Mitsubishi Electronics FR-F700-NA ユーザーズマニュアル

ページ / 416
86
4.3.5
Multiple rating (Pr. 570)
• The initial value and setting range of the following parameters are changed by performing reset and all parameter
clear after changing this parameter setting.
• Reflect the Pr. 570 setting in the following procedure.
1) Change the Pr. 570 setting.
2) Reset the inverter.
3) Perform all parameter clear.
*1
The rated current differs according to the inverter capacity. Refer to rated specifications (page 370).
*2
For the FR-F720-02330(FR-F740-01160) or less, SLD/LD value of applied motor capacity is the same. Refer to rated specifications (page 370).
You can use the inverter by changing the overload current rating specifications according to load applications.
Note that the control rating of each function changes.
Parameter 
Number
Name
Initial Value
Setting 
Range
Description
570
Multiple rating setting
0
0
SLD
Surrounding air temperature 40°C (104°F),
Overload current rating 110% 60s, 120% 3s
(Inverse time characteristics)
1
LD
Surrounding air temperature 50°C (122°F),
Overload current rating 120% 60s, 150% 3s
(Inverse time characteristics)
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 190)
Parameter 
Number
Name
Pr. 570 Setting
Refer to 
Page
0
(initial value)
1
9
Electronic thermal O/L 
relay
Initial Value
SLD rated current 
LD rated current 
22
Stall prevention operation 
level
Setting Range
0, 0.1 to 120%, 9999
0, 0.1 to 150%, 9999
Initial Value
110%
120%
23
Stall prevention operation 
level compensation factor 
at double speed
Setting Range
0 to 150%, 9999
0 to 200%, 9999
Initial Value
9999
9999
48
Second stall prevention 
operation current
Setting Range
0, 0.1 to 120%
0, 0.1 to 150%
Initial Value
110%
120%
56
Current monitoring 
reference
Initial Value
SLD rated current 
LD rated current 
148
Stall prevention level at 
0V input
Setting Range
0 to 120%
0 to 150%
Initial Value
110%
120%
149
Stall prevention level at 
10V input
Setting Range
0 to 120%
0 to 150%
Initial Value
120%
150%
150
Output current detection 
level
Setting Range
0 to 120%
0 to 150%
Initial Value
110%
120%
165
Stall prevention operation 
level for restart
Setting Range
0 to 120%
0 to 150%
Initial Value
110%
120%
557
Current average value 
monitor signal output 
reference current
Initial Value
SLD rated current 
LD rated current 
893
Energy saving monitor 
reference (motor 
capacity)
Initial Value
SLD value of applied 
motor capacity 
LD value of applied 
motor capacity 
CAUTION
When Pr. 570 = "0" (initial value), Pr.260 PWM frequency automatic switchover becomes invalid. (Refer to page 169.)