Mitsubishi Electronics FR-F740P ユーザーズマニュアル

ページ / 410
193
Frequency setting by analog input (terminal 1, 2, 4)
4
4.17.5 Bias and gain of frequency setting voltage (current) 
(Pr. 125, Pr. 126, Pr. 241, C2(Pr. 902) to C7(Pr. 905))
You can set the magnitude (slope) of the output frequency as desired in relation to the frequency setting signal (0
to 5V, 0 to 10V or 4 to 20mADC).
Set Pr. 73 and Pr. 267 to switch between 0 to 5VDC, 0 to 10VDC and 4 to 20mADC. (Refer to page 185)
Parameter 
Number
Name
Initial Value
Setting 
Range
Description
125
Terminal 2 frequency setting gain 
frequency
60Hz
 *4
 0 to 400Hz
Set the frequency of terminal 2 input gain 
(maximum).
126
Terminal 4 frequency setting gain 
frequency
60Hz
 *4
 0 to 400Hz
Set the frequency of terminal 4 input gain 
(maximum).
241
Analog input display unit 
switchover
0
0
Displayed in %
Select the unit of 
analog input display.
1
Displayed in V/mA
C2(902)
Terminal 2 frequency setting bias 
frequency
0Hz
 0 to 400Hz
Set the frequency on the bias side of 
terminal 2 input.
C3(902)
Terminal 2 frequency setting bias 
0%
 0 to 300%
Set the converted % of the bias side 
voltage (current) of terminal 2 input.
C4(903)
Terminal 2 frequency setting gain
100%
 0 to 300%
Set the converted % of the gain side 
voltage (current)  of terminal 2 input.
C5(904)
Terminal 4 frequency setting bias 
frequency
0Hz
 0 to 400Hz
Set the frequency on the bias side of 
terminal 4 input.
C6(904) 
Terminal 4 frequency setting bias 
20%
 0 to 300%
Set the converted % of the bias side 
current (voltage) of terminal 4 input.
C7(905) 
Terminal 4 frequency setting gain
100%
 0 to 300%
Set the converted % of the gain side 
current (voltage) of terminal 4 input.
*1
This parameter can be set when Pr. 160 User group read selection = "0". (Refer to page 201.)
*2
The parameter number in parentheses is the one for use with the parameter unit (FR-PU04/FR-PU07).
*3
This parameter allows its setting to be changed during operation in any operation mode even if "0" (initial value) is set in Pr. 77 Parameter write
selection.
*4
Performing IPM parameter initialization changes the settings. (Refer to page 80)