Mitsubishi Electronics FR-F740P ユーザーズマニュアル

ページ / 410
359
Specification of premium high-efficiency
IPM motor [MM-EFS (1500r/min) series]
7.4 Specification of premium high-efficiency IPM motor 
[MM-EFS (1500r/min) series]
Motor specification
*1
The above characteristics apply when the rated AC voltage is input from the inverter. (Refer to page 346.) Output and rated motor speed are not
guaranteed when the power supply voltage drops.
*2
This excludes the part where the axis passes through.
Motor torque characteristic
The following figure shows the torque characteristic of the premium high-efficiency IPM motor [MM-EFS (1500r/min)
series] when used with an inverter.
MM-EFS 1M4
7
15
22
37
55
75
11K
15K
18K
22K
30K
37K
45K
55K
Compatible 
inverter
FR-F740P- K
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
Continuous 
characteristic 
Rated output 
(kW)
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
Rated torque 
(N m)
4.77 9.55
14
23.6
35
47.7
70
95.5
118
140
191
236
286
350
Rated speed (r/min)
1500
Maximum speed (r/min)
2250
Number of poles
6
8
Maximum torque
120% 60s
Frame number
80M
90L 100L 112M 132S 132M 160M 160L
180M
180L
200L
225S
Moment of inertia  (
×
10
-4
kg m
2
)
20
40
55
110
275
280
760
770 1700 1700 1900 3400 3850 6500
Rated current 
(A)
400V class
1.5
2.8
4
6.5
10
13.5
20
27
33
39.5
55
64
78.5
97
Structure
Totally-enclosed fan-cooled motor. With steel framed legs. (protective structure IP44 
Insulation class
F class
Vibration class
V-15
Environment
Surrounding air 
temperature 
and humidity
-10°C to +40°C (non-freezing) 
 90%RH or less (non-condensing)
Storage 
temperature 
and humidity
-20°C to +70°C (non-freezing) 
 90%RH or less (non-condensing)
Atmosphere
Indoors (not under direct sunlight), and free from corrosive gas, flammable gas, oil mist, dust and dirt.
Altitude
Maximum 1,000m above sea level
Vibration
4.9m/s
2
Mass(kg)
11
15
22
31
50
53
95
100
135
155
215
230
285
REMARKS
· The motor can also be used for applications which require the rated speed of 1800r/min.
CAUTION
• The torque characteristic is when the armature winding temperature is 20°C, and the input voltage to the inverter is
400VAC.
• Constant-speed operation cannot be performed for the speed of 150r/min or less. 
0
150
500
1800
0
140
120
100
60
80
40
20
300
900 1200 1500
2100
2250
80%
66.7%
Speed [r/min]
T
orque[
%
]
Continuous operation
torque
Short time(60s) maximum torque