Mitsubishi Electronics FR-F740P ユーザーズマニュアル

ページ / 410
360
Specification of high-efficiency IPM 
motor [MM-EF (1800r/min) series]
7.5 Specification of high-efficiency IPM motor 
[MM-EF (1800r/min) series]
Motor specification
*1
The above characteristics apply when the rated AC voltage is input from the inverter. (Refer to page 346. Output and rated motor speed are
not guaranteed when the power supply voltage drops.
*2
This excludes the part where the axis passes through. 
Motor torque characteristic
The following figures show the torque characteristics of high-efficiency IPM motors [MM-EF (1800r/min) series]
when used with inverters.
Motor
model
200V class
MM-EF 2
4
7
15
22
37
55
75
11K 15K 18K 22K 30K 37K 45K 55K 75K
-
-
400V class
MM-EF 24
90K 110K
Compatible 
inverter
200V class
FR-F720P- K
0.75 0.75 1.5 2.2 3.7 5.5 7.5
11
15 18.5 22
30
37
45
55
75
-
-
400V class
FR-F740P- K
90
110
Continuous 
characteristic
Rated output 
(kW)
0.4 0.75 1.5 2.2 3.7 5.5 7.5
11
15 18.5 22
30
37
45
55
75
90
110
Rated torque 
(N m)
2.12 3.98 7.96 11.7 19.6 29.2 39.8 58.4 79.6 98.1 117 159 196 239 292 398 477 584
Rated speed (r/min)
1800 (90Hz)
1800 (120Hz)
Maximum speed (r/min)
2700 (135Hz)
2700 (180Hz)
2400 
(160Hz)
Number of poles
6
8
Maximum torque
120%  60s
Frame number
80M
90L 100L
112M
132S
160M
160L
180L
200L
225S
Moment of inertia
 (
×
10
-4
kg m
2
)
10.4 10.4 18.4 36.9 51.2 125 153 274 354 815 815 1050 2215 2400 4300 5200 8700 9500
Rated current 
(A)
200V class
1.6 3.0 5.9 8.7 14.4 22
29
43
55 70.5 83.5 109 136 162 195 272
-
-
400V class
0.8 1.5 3.0 4.4 7.2
11 14.5 21.5 27.5 35
42
57
68
81 96.5 136 160 197
Structure
Totally-enclosed fan-cooled motor (protective structure IP44
)
Insulation class
B class
F class
Environment
Surrounding air 
temperature 
and humidity 
-10°C to +40°C (non-freezing) 
 90%RH or less (non-condensing)
Storage 
temperature 
and humidity
-20°C to +70°C (non-freezing) 
 90%RH or less (non-condensing)
Atmosphere
Indoors (not under direct sunlight), and free from corrosive gas, flammable gas, oil mist, dust and dirt.
Altitude
Maximum 1,000m above sea level
Vibration
4.9m/s
2
Mass(kg)
8.5 9.0
11
15
23
33
38
52
60 105 105 119 167 178 240 290 360 390
CAUTION
• The torque characteristic is when the armature winding temperature is 20°C, and the input voltage to the inverter is 200VAC
or 400VAC.
• Constant-speed operation cannot be performed for the speed of 180r/min or less. 
Speed [r/min]
T
orque[
%
]
0
180
600
1800
2700
0
140
120
100
60
80
75K or lower
40
20
300
900 1200 1500
2100 2400
80%
66.7%
Short time(60s) maximum
torque
Continuous operation
torque
90K or higher
Speed[r/min]
T
orque[
%
]
0
180
600
1800
0
140
120
100
60
80
40
20
300
900
1200 1500
2100 2400
90%
75%
Short time(60s) maximum
torque
Continuous operation
torque