366
Options and products available on the market
By fitting the following options to the inverter, the inverter is provided with more functions.
Appendix 2 Options and products available on the market
Name
Model
Applications, Specifications, etc.
Applicable
Inverter
S
tan
d-alo
ne ty
pe
Parameter unit
(Eight languages)
(Eight languages)
FR-PU07
FR-PU04
FR-PU04
Interactive parameter unit with LCD display
Applicable for all
models
models
Parameter unit with battery
pack
pack
FR-PU07BB(-L)
Parameter unit that enables parameter setting without
connecting the power supply to the inverter.
connecting the power supply to the inverter.
Applicable for all
models
models
Parameter unit
connection cable
connection cable
FR-CB20
Cable for connection of operation panel or parameter unit.
indicates a cable length.(1m, 3m, 5m)
Applicable for all
models
models
Operation panel
connection connector
connection connector
FR-ADP
Connector to connect the operation panel (FR-DU07) and
connection cable
connection cable
Heatsink protrusion
attachment
attachment
FR-A7CN
Attachment for protruding the inverter heatsink at the back of
the enclosure.
the enclosure.
Applicable for the
following
capacities:
FR-F720P-2.2K
to 110K
FR-F740P-0.75K
to 160K
following
capacities:
FR-F720P-2.2K
to 110K
FR-F740P-0.75K
to 160K
Intercompatibility
attachment
attachment
FR-AAT
Attachment for replacing with the FR-F700P series using the
installation holes of the FR-F500.
installation holes of the FR-F500.
Applicable for the
certain capacities
certain capacities
FR-A5AT
Attachment for replacing with the FR-F700P series using the
installation holes of the FR-A100[Excellent] and
FR-A200[Excellent]
installation holes of the FR-A100[Excellent] and
FR-A200[Excellent]
AC reactor
FR-HAL
For harmonic current reduction and inverter input power
factor improvement (total power factor approx. 88%)
factor improvement (total power factor approx. 88%)
Applicable for the
certain capacities
certain capacities
DC reactor
FR-HEL
For harmonic current reduction and inverter input power
factor improvement (total power factor approx. 93%)
factor improvement (total power factor approx. 93%)
For the 55K or
lower
lower
Brake unit
Resistor unit
Resistor unit
FR-BU2
For increasing the braking capability of the inverter (for high
inertia load or negative load)
Brake unit and resistor unit are used in combination
inertia load or negative load)
Brake unit and resistor unit are used in combination
Applicable for the
certain capacities
certain capacities
FR-BR
For the 55K or
lower
lower
MT-BR5
For the 75K or
higher
higher
Power regeneration
common converter
Dedicated stand-alone
reactor for FR-CV
common converter
Dedicated stand-alone
reactor for FR-CV
FR-CV/FR-
CVL
CVL
Unit which can return motor-generated braking energy back
to the power supply in common converter system
to the power supply in common converter system
For the 55K or
lower
lower
Power regeneration
common converter
common converter
MT-RC
Energy-efficient and high-performance brake unit which
regenerates the braking energy generated by the motor to
the power supply.
regenerates the braking energy generated by the motor to
the power supply.
For the 75K or
higher
higher
High power factor
converter
converter
FR-HC
The high power factor converter switches the converter
section on/off to reshape an input current waveform into a
sine wave, greatly suppressing harmonics. (Used in
combination with the standard accessory.)
section on/off to reshape an input current waveform into a
sine wave, greatly suppressing harmonics. (Used in
combination with the standard accessory.)
For the 55K or
lower
lower
MT-HC
For the 75K or
higher
higher
Line noise filter
FR-BSF01
FR-BLF
FR-BLF
For line noise reduction
Applicable for all
models
models
Surge voltage suppression
filter
filter
FR-ASF
Filter for suppressing surge voltage on motor
For the 55K or
lower in the 400V
class
lower in the 400V
class
FR-BMF
Applicable for the
following
capacities:
FR-F740P-5.5K
to 37K
following
capacities:
FR-F740P-5.5K
to 37K
Sine wave
filter
filter
Reactor
MT-BSL
For reducing the motor noise while the motor is driven by an
inverter. Use a reactor and a capacitor in combination.
inverter. Use a reactor and a capacitor in combination.
For the 75K or
higher
higher
Capacitor
MT-BSC