Mitsubishi Electronics FR-F740P ユーザーズマニュアル
368
*1
These instruction codes are used for parameter read and write by using Mitsubishi inverter protocol with the RS-485 communication.
(Refer to page 229 for RS-485 communication)
(Refer to page 229 for RS-485 communication)
*2
Validity and invalidity according to operation mode are as follows:
:Usable parameter
×
:Unusable parameter
*3
" " indicates valid and "
×" indicates invalid of "parameter copy", "parameter clear", and "all parameter clear".
*4
These parameters are communication parameters that are not cleared when parameter clear (all clear) is executed from RS-485 communication.
(Refer to page 229 for RS-485 communication)
(Refer to page 229 for RS-485 communication)
*5
When a communication option is installed, parameter clear (lock release) during password lock (Pr. 297
≠ 9999) can be performed only from the
communication option.
Symbols in the table indicate parameters which function when an option is mounted.
.......FR-A7AX, ....... FR-A7AY, ........ FR-A7AR, ........FR-A7NC, ....... FR-A7ND,
.......FR-A7NL, ....... FR-A7NP, ........ FR-A7NF
.......FR-A7NL, ....... FR-A7NP, ........ FR-A7NF
Appendix 3 Parameter clear, parameter copy and instruction code list
Parameter
Name
Instruction Code
Control Mode-based
Correspondence Table
Parameter
Copy
Parameter
Clear
All
Parameter
Clear
Read
Write
Extended
V/F
control
Simple
magnetic
flux vector
control
IPM motor
control
0
Torque boost
00
80
0
×
×
1
Maximum frequency
01
81
0
2
Minimum frequency
02
82
0
3
Base frequency
03
83
0
×
4
Multi-speed setting (high
speed)
speed)
04
84
0
5
Multi-speed setting (middle
speed)
speed)
05
85
0
6
Multi-speed setting (low
speed)
speed)
06
86
0
7
Acceleration time
07
87
0
8
Deceleration time
08
88
0
9
Electronic thermal O/L relay
09
89
0
10
DC injection brake operation
frequency
frequency
0A
8A
0
11
DC injection brake operation
time
time
0B
8B
0
12
DC injection brake operation
voltage
voltage
0C
8C
0
×
13
Starting frequency
0D
8D
0
14
Load pattern selection
0E
8E
0
×
×
15
Jog frequency
0F
8F
0
16
Jog acceleration/deceleration
time
time
10
90
0
17
MRS input selection
11
91
0
18
High speed maximum
frequency
frequency
12
92
0
19
Base frequency voltage
13
93
0
×
20
Acceleration/deceleration
reference frequency
reference frequency
14
94
0
21
Acceleration/deceleration time
increments
increments
15
95
0
22
Stall prevention operation level
(Torque limit level )
(Torque limit level )
16
96
0
23
Stall prevention operation
level compensation factor at
double speed
level compensation factor at
double speed
17
97
0
×
24
Multi-speed setting (speed 4)
18
98
0
25
Multi-speed setting (speed 5)
19
99
0
26
Multi-speed setting (speed 6)
1A
9A
0
27
Multi-speed setting (speed 7)
1B
9B
0
V/F
V/F
V/F
S
MFVC
S
MFVC
S
MFVC
IPM
IPM
IPM