Graco 15W034 ユーザーズマニュアル

ページ / 6
15W034 Beacon Tower Kit Installation 
2
313542D
15W034 Beacon Tower Kit 
Installation
NOTE: Kit 15W034 is for ProMix 2KS manual systems.
1.
Remove the 3/4 in. (19 mm) knockout on top of the 
EasyKey. Feed the wires through the hole and 
secure the beacon (1) with jam nuts (N) on the 
inside and outside of the box. See F
IG
. 1.
2.
See F
. 4. Install the din rail (7) with two screws (8). 
Install the header (5) on the din rail and connect the 
cable (4) to J5 on the EasyKey display board.
3.
Connect yellow and gray wires from beacon to the 
power terminal. See F
IG
. 2.
4.
Connect orange, brown, and red wires to header (5) 
pins 3, 4, and 5. See F
IG
. 6 on page 6.
5.
To enable the optional audible alarm, connect sky 
blue wire to pin 3 on header (5). See F
IG
. 6 on page 
6. When enabled, it will sound for all system alarms.
6.
When beacon wiring is completed, insulate the end 
of each unused lead wire with insulation tape.
Beacon Signals
NOTE: See the ProMix 2KS operation manual for details 
of the specific alarms.
F
IG
. 1: Install Beacon on EasyKey
F
IG
. 2: Power Terminal Connections
1
TI14040a
N
INPUT A
C
OUTPUT DC
DC
OK
+
-
-
N (-)
  NC
  NC
L (+)
TI14041a
Yellow (+24V)
Gray 
(Common)
Flashing 
Signal/
Audible
Description
Amber
A system warning is active; verify alarm.
Red
A potlife alarm exists. System goes to 
Standby.
Green
Not used.
Audible
A system warning is active; verify alarm.