122193 Beacon Tower Installation
313542D
3
122193 Beacon Tower Installation
Install on a ProMix 2KS
NOTE: Beacon Tower 122193 is for ProMix 2KS auto-
matic systems (ADxxxx or RDxxxx), or manual systems 
with wire harness 15W023 installed.
1.
Remove the 3/4 in. (19 mm) knockout on top of the 
EasyKey. Feed the wires through the hole and 
secure the beacon (1) with jam nuts (N) on the 
inside and outside of the box. See F
IG
. 1.
2.
Connect yellow and gray wires from beacon to the 
power terminal. See F
IG
. 2.
3.
Connect orange, brown, and red wires to header 
pins 6, 7, and 8. See F
. 5 on page 6.
4.
To enable the optional audible alarm, connect sky 
blue wire to pin 6 on header. See F
. 5 on page 6. 
When enabled, it will sound for all system alarms.
5.
When beacon wiring is completed, insulate the end 
of each unused lead wire with insulation tape.
Install on a ProMix 2KE
1.
Disconnect the existing alarm from pins 1 and 2 on 
the terminal strip. See F
IG
. 3. 
2.
Mount the beacon near the control box and secure 
with jam nuts. Feed the wires into the box.
3.
Connect the yellow wire from the beacon to pin 12 
on the terminal strip. 
4.
Connect the gray wire from the beacon to pin 2 on 
the terminal strip. 
5.
Connect either the orange, brown, or red wire to pin 
1 on the terminal strip. 
6.
To enable the optional audible alarm, connect sky 
blue wire to pin 1 on the terminal strip. When 
enabled, it will sound for all system alarms.
7.
When beacon wiring is completed, insulate the end 
of each unused lead wire with insulation tape.
F
IG
. 3. Beacon Connections in Control Box, ProMix 2KE
ti15730a
YELLO
W
GRA
Y
Beacon Wires Schematic
1 2
12
14
ORANGE, BR
O
W
N, OR RED
SKY BLUE