Intrinsically Safe Installation Requirements
1. The installation must meet the requirements of the 
National Electric Code, NFPA 70, Article 504 Resp., 
Article 505, and ANSI/ISA 12.06.01.
2. Multiple earthing of components is allowed only if 
high integrity equipotential system realized between 
the points of bonding.
3. For ATEX, install per EN 60079-14 and applicable 
local and national codes.
Do not substitute or modify system components as 
this may impair intrinsic safety. For installation, 
maintenance, or operation instructions, read 
instruction manuals. Do not install equipment 
approved only for non-hazardous location in a 
hazardous location. See the identification label for 
the intrinsic safety rating for your model.