Graco 3A0869J ユーザーズマニュアル

ページ / 80
Installation 
12
3A0869J
Display Module
1. Use the screws provided 
to mount the bracket for 
the Display Module on the 
front of the Control Box or 
on the wall, as you prefer.
2. Snap the Display Module 
into the bracket.
3. Connect one end of the 
CAN cable (provided) to J6 
on the Display Module (either 
port). 
4. The other end of the cable comes from the factory 
connected as shown, depending on the configura-
tion of your system:
Wall Power Systems 
with USB Module:
Connect the CAN cable 
to P3 on the USB Mod-
ule.
Wall Power Systems 
without USB Module: 
Connect CAN cable to 
J8 on the Advanced 
Fluid Control Module.
Alternator Power Sys-
tems (with or without 
USB Module):
 Connect 
CAN cable to J3 on the 
alternator.
Air Supply
Requirements
Compressed air supply pressure: 75-100 psi 
(517-700 kPa, 5.2-7 bar).
Air hoses: use grounded hoses that are correctly 
sized for your system.
Air regulator and bleed-type shutoff valve: 
include in each air line to fluid supply equipment. 
Install an additional shutoff valve upstream of all air 
line accessories to isolate them for servicing.
Air line filter: a 10 micron or better air filter is rec-
ommended to filter oil and water out of the air supply 
and help avoid paint contamination and clogged 
solenoids.
ti16672a
J6
ti16604a
P3
ti16580a
J8
ti16579a
J3
ti16456a
Trapped air can cause a pump or dispense valve to 
cycle unexpectedly, which could result in serious 
injury from splashing or moving parts. Use bleed-type 
shutoff valves.
If using a Graco electrostatic PRO
 Gun, a shutoff 
valve must be installed in the gun air line to shutoff 
the atomizing and turbine air to the gun. Contact your 
Graco distributor for information on air shutoff valves 
for electrostatic applications.