Installation 
14
3A0869J
Fluid Supply
Requirements
ProMix 2KE models are available to operate air spray or 
air-assisted systems with a capacity of up to 3800 
cc/min. 
Fluid supply pressure tanks, feed pumps, or circu-
lating systems can be used. 
Materials can be transferred from their original con-
tainers or from a central paint recirculating line.
See manual 313599 for Coriolis meter installation 
and operation instructions.
NOTE: The Coriolis meter can be used only on non-IS 
systems 24F080-24F083. When installed on these sys-
tems, the meter’s hazardous location intrinsically safe 
status is voided.
If you are using dynamic dosing, see Fluid Connec-
tions, 
this page. See also Set Up the Fluid Mani-
fold for Dynamic Dosing
,
 page 16.
NOTE: The fluid supply must be free of pressure spikes, 
which are commonly caused by pump stroke change-
over. If necessary, install pressure regulators or a surge 
tank on the ProMix 2KE fluid inlets to reduce pulsation. 
Contact your Graco distributor for additional information.
Fluid Connections
1. See F
IG
. 6. Connect the solvent supply line to the 
1/4 npt(f) solvent valve inlets (SVA and SVB). 
2. Connect the component A supply line(s).
Single color system: connect component supply 
line to the component A1 dose valve inlet (DVA1).
Multiple color system: connect supply lines to the 
component A2 and A3 dose valve inlets (DVA2, 
DVA3). See F
IG
. 6.
NOTE: Solvent supplied by a single source can cause 
cross contamination and damage to the system. Install 
check valves or use separate solvent sources.
NOTE: Paint Recirculating System Only
If you are recirculating paint, use the standard inlet 
on Dose Valve A1 (A2, A3) or Dose Valve B. 
Remove the plug directly opposite it on the dose 
valve for the recirculation outlet. The second port is 
on the back of the valve and must be reached from 
inside the control box.
Another option is to use a tee fitting to
recirculate.
NOTE: Verify that all unused fluid ports on the color 
change valve stack are plugged before operation. An 
open port will leak fluid.
3. Connect the component B line to the component B 
dose valve inlet (DVB).
NOTE: The component A and B fluid meter inlets have 
fluid check valves to prevent backflow from fluid supply 
pressure fluctuations. Backflow can cause ratio inaccu-
racies.
4. Connect the gun fluid supply line between the static 
mixer (SM) outlet and the gun fluid inlet.
• Do not exceed the pressure rating of the lowest 
rated component. See the identification label.
• To reduce the risk of injury, including fluid 
injection, you must install a shutoff valve between 
each fluid supply line and the mix manifold. Use 
the valves to shut off fluid during maintenance 
and service.
F
IG
. 5. Paint Recirculation Port
Second port
ti16338a