Basic Operation 
38
3A0869J
Lock Mode
NOTE: Do not change system type, number of guns, 
hose length, hose diameter, dosing type, or number of 
colors when material is loaded in the system. Change 
these inputs only if system hardware is changed.
If you change one of these inputs, the system locks so 
that you cannot spray or mix. The lock icons display.
Power down and power back up again to clear the lock 
and put the new settings into effect. The lock ensures 
that the selection was intended and prevents operation 
with incorrect settings.
Valve Settings
Dose valves and purge valves are factory set with the 
hex nut 1-1/4 turns out from fully closed. This setting 
limits maximum fluid flow rate into integrator and mini-
mizes valve response time. To open dose or purge 
valves (for high viscosity materials), turn hex nut (E) 
counterclockwise. To close dose or purge valves (for 
low viscosity materials), turn clockwise. See F
IG
. 24.
Shutdown
2. Close main air shutoff valve on air supply line and 
on ProMix 2KE.
3. Non-IS Systems: Shut off ProMix 2KE power
(0 position). NOTE: The system will restart in
Recipe 0.
F
IG
. 23. System Lock Mode
F
IG
. 24. Valve Adjustment
Lock
icons
E