Graco 3A0869J ユーザーズマニュアル

ページ / 80
Use of Optional USB Module
3A0869J
39
Use of Optional USB Module
USB Logs
Job Log 1
See example in F
IG
. 25. The job log records total vol-
umes for each job that the system performs, up to 2000. 
It records the date, time, user number, job number, total 
A volume, total B volume, mix ratio, and the recipe used. 
Job total volumes are in cubic centimeters. A log entry is 
made whenever a new job is initiated, which occurs 
when batch totals are cleared, when the job number is 
incremented from Run Job Number (Screen 38), or 
when a color change is performed. Job information is 
displayed on the Display Module only through use of 
the optional USB Module.
NOTE: User Number, Ratio, and Alarm 1-5 are dis-
played as of 2KE System Software version 1.03.001 
(USB Cube Software version 1.10.001).
Error Log 2
See example in F
IG
. 26. The error log records all errors 
generated by the system, up to 500. It records the date, 
time, error number, error code, and error type for each 
error that occurs. Without the USB, the user can access 
the 50 most recent errors via the Display Module.
NOTE: For both the Job Log and the Error Log, when 
the log is full, new data automatically overwrites old 
data. When data in either log is downloaded via the 
USB, it remains in the module until it is overwritten.
F
IG
. 25. Sample Job Log