System Errors
3A0869J
55
System Errors
NOTE: Do not use the fluid in the line that was dis-
pensed off ratio as it may not cure properly.
System Alarms
System alarms alert you of a problem to help prevent 
off-ratio spraying. If an alarm occurs, operation stops 
and the following occurs:
Alarm buzzer sounds.
Status bar on the Display Module shows the alarm 
icon 
 and code.
Alarm is saved in the date/time stamped log.
System Advisory/Record Codes
Table 6 lists the advisory and record codes. Advisories 
and records do not stop operation or sound an alarm. If 
an advisory occurs, the Status bar on the Display Mod-
ule shows the advisory icon and code. System records 
do not display on the Status bar. Both advisories and 
records are saved in the date/time stamped log, which 
can be viewed on the display or saved to a flash drive 
using optional USB port.
To Clear Error and Restart
NOTE: When an error occurs be sure to determine the 
error code before resetting it. If you forget which code 
occurred, use Run Log Errors (Screens 5-14), page 
44, to view the last 50 errors, with date and time stamps.
To reset errors, see Table 7 anAlarm Troubleshoot-
ing
page 58. Many errors can be cleared by simply 
pressing .
Air Flow Switch (AFS) Function
Air or Air-assisted Guns
The air flow switch (AFS) detects air flow to the gun and 
signals the ProMix 2KE controller when the gun is trig-
gered. The AFS functions with the flow meters to ensure 
that system components are functioning correctly. 
For example, if a flow meter fails or clogs, pure resin or 
catalyst could spray indefinitely if the ProMix 2KE does 
not detect the condition and intervene, which is why the 
AFS is so important. 
If the ProMix 2KE detects through the AFS signal that 
the gun is triggered, yet there is no fluid flow through the 
meter, a Dose Time Alarm (QTA1 or QTB1) occurs after 
40 seconds and the system shuts down.
Operating Without Air Flow Switch
It is not recommended to run without an air flow switch. 
If a switch fails, replace it as soon as possible.
Airless Gun
It is not recommended to use an airless gun with the 
ProMix 2KE. Two issues can arise from operating with-
out an air flow switch:
Without a gun trigger/air flow switch input the Pro-
Mix 2KE does not know it is spraying and will not 
generate a Dose Time Alarm. This means there is 
no way to detect a failed meter. You could spray 
pure resin or catalyst for 2 minutes without knowing.
F
IG
. 56. Display Module Alarm Codes
F
IG
. 57. Error Log Icons
Error Code Indicator
Record - no icon
Alarm icon
Advisory icon