Graco 3A0869J ユーザーズマニュアル

ページ / 80
System Errors
3A0869J
57
Error Codes
Table 5: System Alarm/Advisory/Record Codes
Code
Description
Details
Alarm Codes - Alarm sounds, system stops, icon dis-
plays until problem is solved and alarm is cleared.
CA
Communication Error
43
CAU1
USB Communication Error
43
EQU2
USB Installed when not in Standby
43
SG
Gun Flush Box Error
43
SAD1
SAD2
Atomizing Air During Purge - Gun 1
Atomizing Air During Purge - Gun 2
43
SPSA
SPSB
Purge Volume Error A
Purge Volume Error B
SFA1
SFA2
SFA3
SFB1
PreMix Error - Color 
PreMix Error - Catalyst
43
SHA1
SHA2
SHA3
SHB1
PreFill Error - Color
PreFill Error - Catalyst
43
SM
MixFill Start Error
44
SN
MixFill Complete Error
44
QPD1
QPD2
Potlife Error - Gun 1
Potlife Error - Gun 2
44
R1
Ratio Low Error
44
R4
Ratio High Error
45
QDA1
QDA2
QDA3
QDB1
Overdose A, B Dose too Short
Overdose B, A Dose too Short
46
QTA1
QTA2
QTA3
QTB1
Dose Time A Error
Dose Time B Error
47
QLAX
QLBX
Leak Error A
Leak Error B
47
P6A1
P6B1
Pressure Transducer Error A
Pressure Transducer Error B
48
Advisory Codes - No alarm, system continues operat-
ing, icon displays on active screen until cleared
MFA1
Meter A maintenance due
N/A
MFB1
Meter B maintenance due
N/A
MEA1
Mix valve A1 maintenance due
N/A
MEA2
Mix valve A2 maintenance due
N/A
MEA3
Mix valve A3 maintenance due
N/A
MEB1
Mix valve B maintenance due
N/A
MESA
Solvent valve A maintenance due
N/A
MESB
Solvent valve B maintenance due
N/A
MGA1
Fluid Filter A maintenance due
N/A
MGB1
Fluid Filter B maintenance due
N/A
MGP1
Air Filter maintenance due
N/A
ES
System defaults loaded
N/A
Record Codes - No alarm, system continues operating, 
no icon displays on active screen.
EL
System powered on
N/A
EC
System setup changed
N/A
ES
System defaults loaded
N/A
ET
System performed an autodump after 
a potlife
N/A
EQU1
USB Drive connected while in Standby N/A
Table 5: System Alarm/Advisory/Record Codes
Code
Description
Details