POSSIBLE CAUSE
1. Ignitor  electrode  not  con-
nected to ignitor cable
2. Ignitor cable pinched or wet
3. Piezo ignitor nut is loose
4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode broken
7. Ignitor electrode positioned 
wrong
1. Gas supply turned off or equip-
ment shutoff valve closed
2. Control knob not in PILOT 
position
3. Control knob not pressed in 
while in PILOT position
4. Air  in  gas  lines  when  in-
stalled
5. Depleted gas supply (propane/
LP only)
6. ODS/pilot is clogged
7. Gas regulator setting is not 
correct
REMEDY 
1. Reconnect ignitor cable
2. Free ignitor cable if pinched 
by any metal or tubing. Keep 
ignitor cable dry
3. Tighten nut holding piezo ignitor 
to base panel of log set. Nut is 
located behind base panel
4. Replace ignitor cable
5. Replace piezo ignitor 
6. Replace pilot assembly
7. Replace pilot assembly
1. Turn  on  gas  supply  or  open 
equipment shutoff valve
2. Turn control knob to PILOT 
position
3. Press in control knob while in 
PILOT position
4. Continue holding down control 
knob. Repeat igniting opera-
tion until air is removed
5. Contact local propane/LP gas 
company
6. Clean ODS/pilot (see Cleaning 
and Maintenance, page 21) or 
replace ODS/pilot assembly
7. Replace gas regulator
OBSERVED PROBLEM
When ignitor button is pressed, 
there is no spark at ODS/pilot
When ignitor button is pressed, 
there  is  spark  at  ODS/pilot  but 
no ignition