Mitsubishi Electronics E60 ユーザーズマニュアル

ページ / 415
1. 
LIST OF ALARMS 
1.2 Stop 
Codes 
I - 10 
 
Error No. 
Details 
Remedy 
0108 
OP MODE DUPL (Operation mode 
duplicated) 
Two or more automatic operation modes 
are selected. 
•  Check for a short circuit in the mode 
selection signal wire (memory‚ tape‚ 
MDl). 
•  Check for trouble in the switch.  
•  Check the sequence program. 
0109 
OP MODE SHFT (Operation mode shift) 
The automatic operation mode changed 
to another automatic operation mode. 
•  Return to the original automatic 
operation mode‚ and start automatic 
start. 
0110 
Tape search execution 
Automatic start is not possible as tape 
search is being executed. 
•  Begin automatic start after the tape 
search is completed. 
0112 
Program restart position return incomplete
Automatic start is not possible as the 
axis has not been returned to the restart 
position. 
•  Manually return to the restart position. 
•  Turn the automatic restart valid 
parameter ON, and then execute 
automatic start. 
0113 
Thermal alarm 
Automatic start is not possible because 
a thermal alarm (Z53 TEMP. OVER) has 
occurred. 
•  The NC controller temperature has 
exceeded the specified temperature. 
•  Take appropriate measures to cool the 
unit. 
0115 
In host communication 
Automatic start cannot be executed as 
the NC is communicating with the host 
computer. 
•  Execute automatic start after the 
communication with the host computer 
is completed. 
0138 
Disabled start during absolute position 
detection alarm 
A start signal was input during an 
absolute position detection alarm. 
•  Reset the absolute position detection 
alarm‚ and then input the start signal. 
0139 
Disabled start during zero point 
initialization 
A start signal was input while initializing 
the absolute position detector’s zero 
point. 
•  Complete zero point initialization before 
inputting the start signal. 
0190 
Automatic start disabled 
Automatic start is disabled because 
setup parameters can be set. 
•  Refer to the manual issued by the 
machine manufacturer. 
0191 
Automatic start disabled 
Automatic start was caused during file 
deletion or writing. 
•  Cause automatic start after file deletion 
or writing is completed.