Mitsubishi Electronics E60 ユーザーズマニュアル

ページ / 415
8. SPINDLE 
PARAMETERS 
8.4 Supplement 
II - 285 
(2) Setting the output data 
 
Input the No. of the data to be output to each D/A output channel. 
# No. Abbrev 
Parameter 
name 
3453 
SP253 
DA1NO 
D/A output channel 1 data No. 
3454 
SP254 
DA2NO 
D/A output channel 2 data No. 
 
No. 
Output data 
Original data unit 
Standard setting value 
for output scale  
(Setting values in 
SP255, SP256) 
Standard output 
unit 
Output 
cycle 
ch1: Speed meter 
output 
10V=max. speed 
(0=0V) 
Depends on the 
max. speed 
3.5ms 
ch2: Load meter 
output 
10V=120% load (0=0V) 0 
30-minute rating 
12%/V 
3.5ms 
1 – 
 
 
 
 
Current command 
Rated 100% = 4096 
30-minute rating 
20%/V 
3.5ms 
Current feedback 
Rated 100% = 4096 
30-minute rating 
20%/V 
3.5ms 
4 Speed 
feedback 
r/min 
13 
500(r/min)/V 3.5ms 
5 – 
 
 
 
 
Position droop  
(lower order 16bit) 
0.001deg=64 10 
(10.24)  0.01deg/V 
0.8µs 
Position droop  
(higher order 16bit) 
1deg=(64000
÷65536)  671 10deg/V 
0.8µs 
Feedrate (F
∆T)  
(lower order 16bit) 
0.001deg=64 
173 
(at 3.5ms 
communication) 
10deg/min/V 0.8µs 
Feedrate (F
∆T)  
(higher order 16bit) 
1deg=(64000
÷65536) 
629 
(at 3.5ms 
communication) 
500rpm/V 0.8µs 
10 
Position command 
(lower order 16bit) 
0.001deg=64 10 
(10.24)  0.01deg/V 
0.8µs 
11 
Position command  
(higher order 16bit) 
1deg=(64000
÷65536)  19 (18.64) 
360deg/V 
0.8µs 
12 
Position feedback  
(lower order 16bit) 
0.001deg=64 10 
(0.24) 
0.01deg/V 
0.8µs 
13 
Position feedback  
(higher order 16bit) 
1deg=(64000
÷65536)  19 (18.64) 
360deg/V 
0.8µs 
 
 
 
 
 
80  Control input 1 
81  Control input 2 
82  Control input 3 
83  Control input 4 
84  Control output 1 
85  Control output 2 
86  Control output 3 
87  Control output 4 
HEX Bit 
correspondence  3.5ms