Mitsubishi Electronics AJ65BT-D75P2-S3 ユーザーズマニュアル

ページ / 666
 
 
 
10 - 15 
MELSEC-A
10   ADVANCED POSITIONING CONTROL 
 
10.3.8 Repeated start (FOR condition) 
In a "repeated start (FOR condition)", the data between the "start block data" in which 
"6: FOR condition" is set in "
Da.12   Special start command" and the "start block data" 
in which "7: NEXT start" is set in " Da.12   Special start command" is repeatedly 
executed until the establishment of the conditions set in the "condition data". 
The condition is evaluated at the time of change to the point of "7: NEXT start" (just 
before the positioning control for the point of NEXT start). 
(The "condition data" designation is set in " Da.13   Parameter" of the "start block data" 
in which "6: FOR condition" is set in " Da.12   Special start command".) 
 
Section (2) shows a control example where the "start block data" and "positioning data" 
are set as shown in section (1).   
 
(1)   Setting examples 
 
(a)      Start block data setting example 
 
Axis 1 start 
block data 
Da.10  Shape
Da.11  Start 
data No. 
Da.12  Special 
start command 
Da.13  
Parameter 
1st point 
1: Continue 
6: FOR condition 
2nd point 
1: Continue 
10 
0: Normal start 
– 
3rd point 
0: End 
50 
7: NEXT start 
– 
 
 
 
 
 
 
 
 
 
 
* The "condition data Nos." have been set in " Da.13  Parameter". 
 
(b)      Positioning data setting example 
 
Axis 1 position-
ing data No. 
Da.1  Operation pattern 
01: Continuous positioning control
01: Continuous positioning control
3 00: 
Positioning 
complete 
 
 
10 
11: Continuous path control 
11 00: 
Positioning 
complete 
 
 
50 
01: Continuous positioning control
51 00: 
Positioning 
complete 
 
 
 
(2)   Control examples 
The following shows the control executed when the "start block data" of the 1st 
point of axis 1 is set as shown in section (1) and started.   
<1>  Perform the processing of "positioning data No. 1, 2, 3, 10, and 11" of the 
axis 1. 
<2>  Evaluate the condition set in "condition data No. 5" of the axis 1.
*1
 
  Conditions not established 
  Perform the processing of "positioning 
data No. 50 and 51", and go to <1>. 
 Conditions established    Perform the processing of "positioning data 
No. 50 and 51", and complete the positioning. 
*1 The condition is evaluated at the time of change to the point of NEXT start (just 
before the positioning control for the point of NEXT start).