Aprilaire 8355 ユーザーズマニュアル

ページ / 16
Features
• Four pre-programmed setpoints for each day of the week.
• Fast and easy programming for setting all days of the week 
simultaneously.
• Energy efficient recovery.
• Residual cooling for added air-conditioning efficiency.
• Two “AA” ENERGIZER brand batteries retain program memory, 
even during power outages.
• Low battery indicator.
• Multi-colored LED indicators for system status.
• Zone compatible as master thermostat.
• Fahrenheit/Celsius display option.
• Programmable from 45°F (7°C) to 90°F (32°C).
• Accuracy within ±1 degree.
• Adjustable temperature differential: 1-3 degrees.
• Maintains summer and winter programming.
Replacing Existing Thermostat
1. Turn off power to heating and cooling system.
2. Remove cover of old thermostat to expose wires. Do not 
disconnect wires. (Fig. 1)
3. Label wires per Table 1.
TABLE 1
Old Label
New Label
Description
R, V-VR or VR-R
R
24 VAC 
Y, Y1 or M
Y1
Stage 1 Cooling/Heating Circuit
O or R
O
Reversing Valve (Cooling Mode)
B
B
Reversing Valve (Heating Mode)
G or F
G
Fan Contactor Circuit
Y2
Y2
2nd Stage Cooling Circuit
W1 or W2 or W-U
W2
2nd Stage Heating Circuit
L or X
L
System Monitor LED
E
E
Emergency Heating Circuit
C, X or B
C
24 VAC, Transformer Common Side
NOTE: This thermostat requires a 24V AC common wire for proper operation.
4. After labeling wires, remove wires from terminals.
5. Remove existing thermostat base from wall.
6. Refer to the following section for instructions on how to 
install thermostat.
2