Drolet DH04200 ユーザーズマニュアル

ページ / 16
 
 
 
TROUBLESHOOTING GUIDE 
 
 
PROBLEMS 
 
CAUSES 
 
SOLUTION 
 
ON POSITION 6 (MAXIMUM) 
THE FLAME IS LONG AND 
SMOKY, THERE IS SUIT 
BUILD UPON THE GLASS. 
 
Position 6 was reached too 
quickly. 
 
1.  Set flow regulating handle 
to position 1; 
2. wait for combustion to 
stabilize; 
3. Progressively 
increase 
flow 
to desired position. 
NOTE 
: SEE LIGHTING 
PROCEDURES. 
 
 
Maximum flow is too high. 
1.  Set flow to a lower position; 
2.  Call a qualified technician 
to adjust the valve. 
 
ON POSITION 1 (MINIMUM) 
THE FLAME PRODUCES 
SMOKE AND SUITS THE 
GLASS. 
Cleaning tee and/or burner are 
dirty. 
1. 
Activate cleaning tee 
according to procedures; 
2.  Schedule at the next shut 
off to clean the burner. 
 
 
Orifice of plunger is partially 
plugged. 
1. Progressively 
increase 
flow 
to position ‘’6’’; 
2.  Push in many consecutive 
times on the thermostatic 
regulator bottom to remove 
dirt form the orifice. 
 
NOTE :  If the problem persist, 
you may have to remove and 
clean out the valve with alcohol.  
Call  your specialized 
technician. 
 
ON POSITION 1 (MINIMUM) 
THE FLAME PRODUCES 
SMOKE AND SUITS THE 
GLASS. 
Flow is to low. 
1.  Slightly  increase  the  flow 
regulating handle; 
2. 
Call a specialized 
technician. 
 
 
Page 11 of 15