Drolet DH04200 Manual Do Utilizador
TROUBLESHOOTING GUIDE
PROBLEMS
CAUSES
SOLUTION
ON POSITION 6 (MAXIMUM)
THE FLAME IS LONG AND
SMOKY, THERE IS SUIT
BUILD UPON THE GLASS.
Position 6 was reached too
quickly.
1. Set flow regulating handle
to position 1;
2. wait for combustion to
stabilize;
3. Progressively
increase
flow
to desired position.
NOTE
: SEE LIGHTING
PROCEDURES.
Maximum flow is too high.
1. Set flow to a lower position;
2. Call a qualified technician
2. Call a qualified technician
to adjust the valve.
ON POSITION 1 (MINIMUM)
THE FLAME PRODUCES
SMOKE AND SUITS THE
GLASS.
THE FLAME PRODUCES
SMOKE AND SUITS THE
GLASS.
Cleaning tee and/or burner are
dirty.
dirty.
1.
Activate cleaning tee
according to procedures;
according to procedures;
2. Schedule at the next shut
off to clean the burner.
Orifice of plunger is partially
plugged.
plugged.
1. Progressively
increase
flow
to position ‘’6’’;
2. Push in many consecutive
times on the thermostatic
regulator bottom to remove
dirt form the orifice.
regulator bottom to remove
dirt form the orifice.
NOTE : If the problem persist,
you may have to remove and
clean out the valve with alcohol.
Call your specialized
technician.
you may have to remove and
clean out the valve with alcohol.
Call your specialized
technician.
ON POSITION 1 (MINIMUM)
THE FLAME PRODUCES
SMOKE AND SUITS THE
GLASS.
THE FLAME PRODUCES
SMOKE AND SUITS THE
GLASS.
Flow is to low.
1. Slightly increase the flow
regulating handle;
2.
Call a specialized
technician.
technician.
Page 11 of 15