Desa NZ100 ユーザーズマニュアル

ページ / 32
www.desatech.com
118621-01B
20
INSpECTING HEATER
Check  pilot  flame  pattern  and  burner  flame 
pattern often.
PILOT FLAME PATTERN
Figure 29 shows a correct pilot flame pattern. 
Figure 30 shows an incorrect pilot flame pat-
tern. The incorrect pilot flame is not touching 
the thermocouple. This will cause the thermo-
couple to cool. When the thermocouple cools, 
the heater will shut down.
If  pilot  flame  pattern  is  incorrect,  as  shown 
in Figure 30
•  turn heater off (see To Turn Off Gas to Ap-
pliance, page 16)
•  see Troubleshooting, page 22
Note: The pilot flame on natural gas units will 
have a slight curve, but flame should be blue 
and have no yellow or orange color.
bURNER FLAME PATTERN
Figure 31 shows the burners in the ON and 
OFF positions. Burners will come on and go off 
when the remote control is set in the manual 
on mode or thermostat mode.
Figure 32 shows a correct burner flame pat-
tern.  Figure  33  shows  an  incorrect  burner 
flame pattern.
If burner flame pattern is incorrect, as shown 
in Figure 33
•  turn heater off (see To Turn Off Gas to Ap-
pliance, page 16)
•  see Troubleshooting, page 22
Thermocouple
Pilot 
Burner
Pilot 
Burner
Thermocouple
Blue Flame
Yellow 
Flame
Figure 29 - Correct Pilot Flame Pattern
Figure 30 - Incorrect Pilot Flame Pattern
Figure 32 - Correct Burner Flame Pattern 
Figure 33 - Incorrect Burner Flame 
Pattern
Figure 31 - Burner Patterns
Burners ON
Burners OFF
OPERATING 
bLOWER
This heater has a thermostatic blower that will 
automatically turn ON or OFF.
Note: Your heater and thermostat blower will 
not  turn  on  and  off  at  the  same  time.  The 
heater may run for several minutes before the 
blower turns on. After the heater modulates to 
the pilot position, the blower will continue to 
run. The blower will shut off after the heater 
cabinet temperature decreases.
Note: It is safe to operate heater with blower 
turned off. However, the blower helps distrib-
ute heated air from the heater.
OpERATING HEATER
Continued