21
118621-01B
CLEANING AND 
MAINTENANCE
  WARNING:  Turn  off  heater 
and let cool before cleaning.
  CAUTION:  You  must  keep 
control areas, burner and circu-
lating air passageways of heater 
clean.  Inspect  these  areas  of 
heater  before  each  use.  Have 
heater  inspected  yearly  by  a 
qualified service person. Heater 
may need more frequent clean-
ing  due  to  excessive  lint  from 
carpeting, bedding material, pet 
hair, etc.
  WARNING:  Failure  to  keep 
the  primary  air  opening(s)  of 
the burner(s) clean may result in 
sooting and property damage.
ODS/PILOT AND bURNER
Use  a  vacuum  cleaner,  pressurized  air  or 
small, soft bristled brush to clean.
bURNER PILOT AIR INLET
The primary air inlet holes allow the proper 
amount of air to mix with the gas. This pro-
vides a clean burning flame. Keep these holes 
clear of dust, dirt and lint. Clean these air inlet 
holes prior to each heating season. Blocked 
air holes will create soot. We recommend that 
you clean the unit every three months during 
operation and have heater inspected yearly 
by a qualified service person.
We also recommend that you keep the burner 
tube and pilot assembly clean and free of dust 
and dirt. To clean these parts we recommend 
using compressed air no greater than 30 PSI. 
Your local computer store, hardware store or 
home center may carry compressed air in a 
can. If using compressed air in a can, please 
follow the directions on the can. If you don't 
follow directions on the can, you could dam-
age the pilot assembly.
1.  Shut off the unit, including the pilot. Allow 
the unit to cool for at least thirty minutes.
Figure 34 - Pilot Air Inlet
Pilot Assembly
Pilot Air Inlet
2.  Inspect burner, pilot for dust and dirt.
3.  Blow air through the ports/slots and holes 
in the burner.
4.  Never insert objects into the pilot tube.
Clean the pilot assembly also. A yellow tip on 
the pilot flame indicates dust and dirt in the 
pilot assembly. There is a small pilot air inlet 
about two inches from where the pilot flame 
comes out of the pilot assembly (see Figure 
34). With the unit off, lightly blow air through 
the air inlet. You may blow through a drinking 
straw if compressed air is not available.
CAbINET
Air Passageways
Use pressurized air to clean.
Exterior
Use a soft cloth dampened with a mild soap 
and  water  mixture.  Wipe  the  cabinet  to  re-
move dust.
SERVICE HINTS
When Gas Pressure Is Too Low
•  pilot will not stay lit
•  burner will have delayed ignition
•  heater will not produce specified heat
•  propane/LP gas supply may be low
You may feel your gas pressure is too low. If 
so, contact your local natural or propane/LP 
gas supplier.
TECHNICAL SERVICE
You may have further questions about instal-
lation,  operation  or  troubleshooting.  If  so, 
contact  DESA  Heating  Products’  Technical 
Service  Department  at  1-866-672-6040. 
When  calling  please  have  your  model  and 
serial numbers of your heater ready.
You can also visit DESA Heating Products’ tech-
nical service web site at www.desatech.com.