Empire Comfort Systems DVX42DP91(N,P)-1 ユーザーズマニュアル

ページ / 72
25613-0-0309
Page 49
1.  To wire Junction Box Receptacle, remove the tab on the side of the 
receptacle  (hot  side)  to  split  receptacle. This  will  be  required  to 
separate blower and valve circuits.
2.  Power for switched and live sides of Duplex Receptacle must come 
from the same power source. (One circuit breaker on main panel must 
switch all power off.)
3.  From the wall box to the fireplace a 3-wire conductor with ground is 
recommended, however (2) two-wire conductors with grounds may be 
used in place of a 3-wire conductor with a ground if the black wires 
from the thermostat and blower switch are identified. 
4.  Two wall switches, or a wall switch and thermostat may be used to 
activate the two receptacle plugs independently.
The intermittent pilot (120/24 volt system) is ON when the main 
burner is ON. When the main burner is OFF the intermittent pilot 
is OFF.
The pilot flame should envelop 3/8 to 1/2 inch (10 to 13 mm) of 
the tip of the flame rod.
To adjust:
1. Remove the pilot adjustment cover screw.
2. Turn the inner adjustment screw clockwise 
 to de-
crease or counterclockwise 
 to increase pilot flame. 
Pilot adjustment is shipped at full flow rate. Turn the inner 
adjustment screw clockwise
 if the inlet pressure is 
too high.
3. Replace the cover screw after the adjustment to prevent gas 
leakage.
Label all wires prior to disconnection when servicing controls. 
Wiring  errors  can  cause  improper  and  dangerous  operation. 
Verify proper operation after servicing.
Figure 70
Provided on the intermittent pilot wiring harness are two (2) stripped 
and bare wires that are labeled THERMOSTAT. The wires will be 
used for attachment of 24 volt thermostat, optional FWS-1 wall 
switch or will attach into the receiver on an optional FRBC, FRBTC 
or FREC remote control.
Installation of Remote Receiver 
Place remote receiver on the floor of fireplace behind the louver as 
far forward as possible.
Attention: The Velcro loop and hook are not necessary in this 
installation but can be used to secure remote receiver.
ELECTRICAL CONNECTION (Figure 70)
The DVX Intermittent Pilot Models with optional fan requires 120 
VAC electrical hookup to the electrical box (installed).
The appliance, when installed, must be electrically grounded in 
accordance with local codes or, in the absence of local codes, 
with the National Electrical Code, ANSI/NFPA 70, if an external 
electrical source is utilized. 
CAUTION: ALL WIRING SHOULD BE DONE BY A QUALI-
FIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH 
ALL LOCAL, CITY AND STATE BUILDING CODES. BEFORE 
MAKING THE ELECTRICAL CONNECTION, MAKE SURE 
THAT MAIN POWER SUPPLY IS DISCONNECTED. THE AP-
PLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY 
GROUNDED IN ACCORDANCE WITH LOCAL CODES OR, 
IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL 
ELECTRICAL CODE ANSI/NFPA 70 (LATEST EDITION).
Figure 71
INTERMITTENT PILOT OPERATING INSTRUCTIONS
INTERMITTENT PILOT WIRING DIAGRAM