TallyGenicom 2440 ユーザーガイド

ページ / 150
Set-Up mode
Special mode
4-12
INTERFACE menu
Parameter
Value
Description
BUFFER
2KBYTE/16KBYTE/
64KBYTE/128KBYTE/
256KBYTE
Selects the size of the interface buffer.
I/F TYPE
PARALLEL/USB/ 
SERIAL/ETHERNET/ 
AUTO
Selects the type of interface to the com-
puter.
AUTO: All interfaces are ready for com-
munication. The printer communicates 
with the interface from which it first 
receives data. The interface is active until 
the input buffer becomes empty.
PAPER EMPTY
OFFLINE
ONLINE
Sets printer to offline or online mode 
after paper empty.
PARALLEL
NIBBLE/UNI DIR/ 
M307/TGNet III
Selects the transmission mode of the 
parallel interface.
I-PRIME
BUFFER PRINT/
BUFFER CLEAR/
INVALID
Behavior of the printer after receiving an 
Init/Prime signal.
BAUD RATE
4800 BPS/9600 BPS/19200 
BPS
/38400 BPS
The baud rate is in bits per second. 
Select the same baud rate as that used by 
your computer or modem.
PARITY
NONE/EVEN/ODD
Parity setting; select the same word par-
ity setting that is used by your computer 
or modem.
None causes transmission in both direc-
tions without parity bit. Even: The bytes 
are checked to ensure they have even 
parity. Odd: The bytes are checked to 
ensure they have odd parity.
DATA BIT
8 BIT/7 BIT
Word Length setting; select the same 
word length setting that is used by your 
computer or modem.
8 bit: 8 Data bits per data byte. 7 bit: 7 
Data bits per data byte.
STOP BIT
1/2
Word Length setting; select the same 
word length setting that is used by your 
computer or modem.
Selcts 1 or 2 stop bit per data byte.
PROTOCOL
READY/BUSY
XON/XOFF
Selects the type of protocol, i.e. a certain 
set of rules and procedures for ensuring 
error-free data exchanges between com-
puter and printer.