Chassis Management and Monitoring Commands
page 2-48
OmniSwitch CLI Reference Guide
September 2009
show power
Displays the hardware information and current status for chassis power supplies.
show power [supply] [number]
Syntax Definitions
supply
Optional command syntax. 
number
The single-digit number for a specific power supply installed in the 
chassis. If no power supply number is specified, information for all 
power supplies is displayed.
Defaults
N/A
Platforms Supported
OmniSwitch 6400, 6850, 6855, 9000, 9000E.
Usage Guidelines
• When the show power command is entered on stackable switches, information is displayed only for 
power supplies that are installed in the chassis and powered on. If a power supply is present in a power 
supply bay, but the power supply is unplugged or its on/off switch is in the off position, the power 
supply is not listed in the command output.
• On OmniSwitch chassis-based switches, power supplies are numbered from top to bottom. For 
example, a power supply installed in the top position in the chassis is Power Supply 1, or PS-1. 
• On OmniSwitch chassis-based switches, power supplies are numbered from left to right. For detailed 
slot numbering information, see the “Chassis and Power Supplies” chapter of your Hardware Users 
Guide
.
Examples
-> show power
Slot  PS   Wattage   Type   Status     Location
----+----+---------+------+-----------+----------
      1     600      AC    UP           Internal
      2     600      AC    UP           Internal
      3     --       --    --           --     
      4     600      IP    UP           External
      5     600      IP    UP           External
      6     600      IP    UP           External
      7     600      IP    UP           External
-> show power 5
Module in slot PS-5
(Power Shelf slot 5)
  Model Name:                    OS-IPS-600A,
  Description:                   ILPS AC,
  Part Number:                   902252-10,