Alcatel-Lucent 6850-48 参照ガイド
Chassis Management and Monitoring Commands
page 2-48
OmniSwitch CLI Reference Guide
September 2009
show power
Displays the hardware information and current status for chassis power supplies.
show power [supply] [number]
Syntax Definitions
supply
Optional command syntax.
number
The single-digit number for a specific power supply installed in the
chassis. If no power supply number is specified, information for all
power supplies is displayed.
chassis. If no power supply number is specified, information for all
power supplies is displayed.
Defaults
N/A
Platforms Supported
OmniSwitch 6400, 6850, 6855, 9000, 9000E.
Usage Guidelines
• When the show power command is entered on stackable switches, information is displayed only for
power supplies that are installed in the chassis and powered on. If a power supply is present in a power
supply bay, but the power supply is unplugged or its on/off switch is in the off position, the power
supply is not listed in the command output.
supply bay, but the power supply is unplugged or its on/off switch is in the off position, the power
supply is not listed in the command output.
• On OmniSwitch chassis-based switches, power supplies are numbered from top to bottom. For
example, a power supply installed in the top position in the chassis is Power Supply 1, or PS-1.
• On OmniSwitch chassis-based switches, power supplies are numbered from left to right. For detailed
slot numbering information, see the “Chassis and Power Supplies” chapter of your Hardware Users
Guide.
Guide.
Examples
-> show power
Slot PS Wattage Type Status Location
----+----+---------+------+-----------+----------
1 600 AC UP Internal
2 600 AC UP Internal
3 -- -- -- --
4 600 IP UP External
5 600 IP UP External
6 600 IP UP External
7 600 IP UP External
-> show power 5
Module in slot PS-5
(Power Shelf slot 5)
Model Name: OS-IPS-600A,
Description: ILPS AC,
Part Number: 902252-10,