LINK OAM Commands
OmniSwitch CLI Reference Guide
September 2009
page 29-21
efm-oam errored-frame-seconds-summary   
Configures the threshold, window and notify-status for errored-frame-seconds-summary on a port. The 
Errored Seconds are the time in seconds in which at least one frame error has occurred.
efm-oam port slot/port[-port2] errored-frame-seconds-summary [threshold threshold_seconds
[window 
window_seconds] [notify {enable | disable}]
 Syntax Definitions
slot/port
The slot number for the module and the physical port number on that 
module (e.g. 3/1 specifies port 1 on slot 3).
-port2
The last port number in a range of ports that you want to configure on 
the same slot (e.g 3/1-4 specifies ports 1,2,3, and 4 on slot 3). 
threshold_symbols
Specifies the frame error threshold number.
window_seconds
Specifies the window of time in which the frame errors will be 
measured.
enable
Enables notification of the Errored Frame Seconds Summary event.
disable
Disables notification of the Errored Frame Seconds Summary event.
Defaults
Platforms Supported
OmniSwitch 6400, 6850, 6855.
Usage Guidelines 
• The various options, threshold, window and notify can be issued in any order. However, at least one 
option has to be entered. 
• To enter many ports in a single command, use a hyphen to specify a range of ports (e.g. 3/1-16).
Examples
-> efm-oam port 1/1 errored-frame-seconds-summary threshold 1 window 700 notify 
enable
-> efm-oam port 1/1 errored-frame-seconds-summary notify disable
-> efm-oam port 2/1-4 errored-frame-seconds-summary threshold 1 window 700 notify 
enable
-> efm-oam port 2/1-2 errored-frame-seconds-summary notify disable
parameter
default
threshold_symbols 
1 errored frame second
window_seconds
60 seconds. (600 dsec).
enable | disable