LINK OAM Commands
OmniSwitch CLI Reference Guide
September 2009
page 29-19
efm-oam errored-frame   
Configures an error frame threshold or window on a LINK OAM port and set notification status for 
errored frame events. When the number of frame errors exceeds a threshold within a given window 
defined by a period of time (for example, 10 frames in 1 second had errors), an Errored Frame Event is 
generated. 
efm-oam port slot/port[-port2] errored-frame [threshold threshold_symbols] [window 
window_seconds] [notify {enable | disable}]
 Syntax Definitions
slot/port
The slot number for the module and the physical port number on that 
module (e.g. 3/1 specifies port 1 on slot 3).
-port2
The last port number in a range of ports that you want to configure on 
the same slot (e.g 3/1-4 specifies ports 1,2,3, and 4 on slot 3). 
threshold_symbols
Specifies the frame error threshold number.
window_seconds
Specifies the window of time, in which the frame errors will be 
measured. The duration should be in units of 100ms.
enable
Enables notification of the Errored Frame event.
disable
Disables notification of the Errored Frame event.
Defaults
Platforms Supported
OmniSwitch 6400, 6850, 6855.
Usage Guidelines 
• The various options, threshold, window and notify can be issued in any order. However, at least one 
option has to be entered.
• To enter many ports in a single command, use a hyphen to specify a range of ports (e.g. 3/1-16).
Examples
-> efm-oam port 1/1 errored-frame threshold 10 window 32 notify enable
-> efm-oam port 1/1 errored-frame notify disable
-> efm-oam port 2/1-4 errored-frame threshold 10 window 32 notify enable
-> efm-oam port 2/1-2 errored-frame notify disable
parameter
default
threshold_symbols  1 frame error
window_seconds
1 second (10 dsec)
enable | disable
enable