Alcatel-Lucent 6850-48 参照ガイド

ページ / 3444
BFD Commands
page 39-4
OmniSwitch CLI Reference Guide
September 2009
ip bfd-std transmit
Configures the global transmit time interval for BFD control packets. This command specifies the mini-
mum amount of time BFD waits between each transmission of control packets. 
ip bfd-std transmit transmit-interval
Syntax Definitions
transmit-interval
The transmit time interval, in milliseconds. The valid range is 100–999.
Defaults
Platforms Supported
OmniSwitch 6400, 6850, 6855, 9000, 9000E
Usage Guidelines
• The transmit time interval is also configurable at the BFD interface level. Note that configuring the 
global value with the ip bfd-std transmit command does not override the value set for the interface 
using the ip bfd-std interface transmit command.
• The global transmit time interval serves as the default interval value for a BFD interface. The default 
interval value is overridden when a specific value is configured for the interface. 
Examples
-> ip bfd-std transmit 500
Release History
Release 6.3.4; command was introduced.
Related Commands
MIB Objects
alaBfdGlobalTxInterval
parameter
default
transmit-interval
100 milliseconds
Configures the transmit time interval for a specific BFD interface.
Displays the BFD global status and general configuration parameters.