Printronix SL5000r 参照ガイド

ページ / 394
74
Chapter
2
Printing Adjustments
Running Media Profile
The Media Profile printout shows the relationship of the Paper Out Threshold 
and the Gap/Mark Threshold values, illustrates if and when each label length 
indicator is detected, and shows the difference between the label length 
indicators and the label. The profile printout (see Figure 1 on page 75) helps 
you set the thresholds for difficult media. This includes pre-printed labels, 
labels with poor gap/media dynamic range, and smart labels that have 
embedded RFID tags.
Once Media Profile is initiated, the printer will continue to advance media and 
print the profile in landscape orientation until you press 
 to stop printing.
NOTE: Verify the CALIBRATE CTRL menu Gap/Mark Sensor option (Gap, 
Mark, Advanced Gap, Advanced Notch, or Disable) matches the 
installed media. See “Sensing Different Media Types” on page 71.
You will need a minimum installed label width of two inches to support 
the Profile printout.
Ensure the media sensors are horizontally positioned to permit 
sensing of the label length indicators. See “Positioning The Media 
Sensors” on page 66
.
Ensure the Print Mode option selected in the QUICK SETUP menu 
matches the media installed. Select “Direct” for heat sensitive media 
(no ribbon required) or “Transfer” for thermal transfer media (ribbon 
required).
1.
Press 
 to place the printer in Menu mode.
2.
Press 
↓ and 
 together until “ENTER SWITCH UNLOCKED” displays.
3.
Press 
 
until “CALIBRATE CTRL” displays.
4.
Press 
↓ until “Media Profile/Profile Print” displays and then press 
. (The 
printer will continue to print the profile until you press 
.)
The printer will advance media and continue to print a dynamic profile 
image depicting the relationship of the label and any label length 
indicators detected.
5.
Press 
. The printer will stop printing.
6.
Press the PAUSE key until “OFFLINE” displays.
NOTE: The Gap/Mark and Paper Out Threshold values shown on the Profile 
printout represent the last values determined from a successful Auto 
or Manual Calibrate or the factory default values if no Auto or Manual 
Calibrate was performed.
..
.
..
.