To avoid this problem, increase the Threshold Range value to 60% or 70% in 
the CALIBRATE CTRL menu (the default is 50%), then run an Auto Calibrate 
again (Cross-Ref to Auto Calibrate).
NOTE: Any changes to Threshold Range will not take effect until you run an 
Auto Calibrate again.
This will raise the Gap/Mark threshold high enough so that the printer will not 
falsely use the antenna as the gap (top-of-form).
255
191
127
063
000
Paper Out(110)
Gap(072)
Detected Amplitude 
of the Antenna
Detected Amplitude 
of the Gap
Media Sensor 
Position
Indicates Type of Gap/Mark 
Sensing Selected
FEED