Printronix SL5000e ユーザーズマニュアル

ページ / 398
196
Chapter
3
Emulation Submenus
Absorb After ^PY
Absorb Motion. The paper motion line terminator immediately following 
the graphics ^PY command will be ignored.
Absorb All. The system ignores all the data following ^PY until a host 
generated terminator is detected and ignored.
Disable. System terminators following a graphics command are sent to 
the printer and result in paper motion.
The factory default is Absorb Motion.
Active
Yes. When enabled, all data is parsed by the PPI2 emulation. Non-PPI2 
data is absorbed.
No. When disabled, all data is passed to the LP+ emulation.
For information on setting the LP+ Text Mode through the host data stream, 
refer to the 
PPI2 Programmer’s Reference Manual.
The factory default is Yes.
Active Char Set
(From page 158, page 161, page 170, page 173.) Selects which group of 
character sets (Primary or Secondary) will be active.
The factory default is Secondary Set.
AI 00 Spaces
(From page 176.) This option is designated for EAN/UCC-128 barcodes 
whose application identifier (AI) is 00.
Disable. The printable data field is printed with the AI enclosed in 
parentheses. This is the standard EAN/UCC-128 format.
Enable. The printable data field is printed with the UCC fields separated 
by spaces. This option is IGP-X00 compatible.
The factory default is Disable.
Alt. Char Set
Set 1. Interprets data in the range of hex 80 through hex 9F as a control 
code.
Set 2. Prints data in the range of hex 80 through hex 9F.
The factory default is Set 1.