Interleaved 2/5 (I-2/5) and German I-2/5
 249
Interleaved 2/5 (I-2/5) and German I-2/5
The Interleaved 2/5 and German I-2/5 bar code structure is shown in Figure 
15 
and described below.
Figure 15. Interleaved 2/5 and German I-2/5 Structure
Quiet Zone
Both ends of the bar code structure have blank quiet zones. The quiet zones 
must be at least 0.25 inches wide and completely blank to ensure accurate 
reading of the start/stop codes and to prevent adjacent bar codes from 
overlapping. You must provide sufficient space on the form for the quiet 
zones.
Start/Stop Codes
Unique start and stop codes permit bidirectional scanning. Both start and stop 
codes contain bars and spaces. They are automatically produced.
Data Field
The bar code symbol uses a series of wide and narrow bars and spaces to 
represent numeric characters. The structure is 2 wide elements (bars or 
spaces) and 3 narrow elements. In the bar code, two characters are 
interleaved (paired); bars are used to represent the first character in the pair 
and spaces are used to represent the second character in the pair. While 
Interleaved 2/5 has a variable data field, German I-2/5 is restricted to 11 or 13 
digits.
Readable Data
The optional readable data field provides a readable interpretation of the bar 
code data. It can be printed above or below the bar code symbol.
Check Digit
The modulo-10 check digit can be inserted into the bar code to verify accurate 
scanning. German I-2/5 bar codes have the check digit inserted automatically.
DATA FIELD
QUIET
QUIET
START
STOP
LOWER GUARD BAND
CODE
CODE
ZONE
ZONE
OPTIONAL READABLE DATA FIELD
CHECK DIGIT
OPTIONAL
SR, SC
HEIGHT
POSITION
UPPER GUARD BAND