Pump Timer and Final Rinse Timer
The timers have the following user-defined settings:
1. Adjustable time range
2. Timer knob setting
3. 50 Hz or 60 Hz setting
4. Indicator light (“ON” when timer is counting)
The Pump Timer is an OFF DELAY timer.
The Final Rinse Timer is an ON DELAY timer.
Each timer is clearly marked with a tag noting the
time set by the factory.
To Replace a Timer:
— Disconnect power to the machine at the main service switch.
— Remove the defective timer and install the replacement.
— Adjust the new timer setting to match the setting of the original timer.
To Check the Pump Timer Setting:
To Check the Final Rinse Timer Setting:
— Turn the power on.
— Turn the power on.
— Place an object on the conveyor.
— Place on object on the conveyor.
— Press the Green start button. The
— Press the Green start button. The conveyor will start.
conveyor will start.
— When the object enters the tunnel the pumps will start.
— When the object enters the load end
— Wait for the final rinse to begin.
tunnel the pumps will start.
— Press the Red stop button the instant the final rinse begins.
— Wait for the object to exit the tunnel at
— Open the power rinse tank door and
the unload end.
measure the distance between the object and
— When the pumps stop, push the
the final rinse pipes.
conveyor shut-off shelf  to stop
— The object should be 2 feet from
the conveyor.
entering the final rinse area.
— Measure the distance between the exit
— If the distance is less than 2 feet between the object and
end of the tunnel and the object.
the final rinse pipes then, decrease the final rinse
— The object should be about 1 foot past
timer setting 10 seconds. Continue this
the end of the tunnel.
process until the proper distance is reached.
— If the distance is less than 1 foot,
increase the pump timer setting 10
— Run a final test to check both timer settings.
seconds. Continue to increase the timer
setting in 10 second increments until
the proper distance is reached.
— If the measured distance is greater than
1 foot, decrease the pump timer setting
10 seconds. Continue to decrease the timer setting in
10 second increments until the proper distance is reached.
Basic Service ________________
 
Electrical Service
Basic Service • Electrical