Temperature Probe Error 
All probes are typically type-K probes.  All temperature readings normally associated with a 
type-K probe are considered valid by the controller.  However, if the probes become 
disconnected or otherwise open, the controller will sound the buzzer and scroll 
T E M P E R A T U R E   P R O B E   E R R O R
 on line 1 of the display.  The second line will display 
the probe number(s) of the defective probe(s). 
1
 is water temperature probe 
2
 is heater sheath temperature probe 
3
 is sanitizing tank probe 
 
Pressing any key shuts the buzzer off, but will not remove the error message.  The only way 
to remove the error message is to resolve the probe connection problem. 
When these probe errors occur, all outputs are shut off. 
External DC Error 
The controllers DC I/O connector has a +5VDC supply.  This supply is protected against 
over-currents.  Should this occur, the unit will disconnect the supply and report 
E X T E R N A L   D C   E R R O R
.  The outputs are shut down and the only way to reset this is to 
resolve the problem (most likely a short).  Again, pressing any key will shut off the buzzer. 
Omron Messages 
The Omron Inverter may have errors or warnings of its own. Here’s a list of errors flagged.  
In some cases, the Omron inverter will shut down (and let the motor coast to a stop).   
Error detected  Message scrolled 
OC 
O V E R C U R R E N T   E R R O R  
OV 
O V E R V O L T A G E   E R R O R  
OL2 
I N V E R T E R   O V E R L O A D   E R R O R
OH 
I N V E R T E R   O V E R H E A T   E R R O R
EFx/STP 
E X T E R N A L   F A U L T   E R R O R  
Fx 
I N T E R N A L   F A U L T   E R R O R  
OL1 
M O T O R   O V E R L O A D   E R R O R  
OL3 
O V E R T O R Q U E   E R R O R  
UV1 
U N D E R V O L T A G E   E R R O R  
GF 
G R O U N D   F A U L T   E R R O R  
CE 
C O M M U N I C A T I O N S   E R R O R  
OFF 
N O   P O W E R   E R R O R  
 
 