Part 3: OPERATION
Table 3.2
Controls and Indicators
Dishwasher and Booster
3.2 Description of Operator Controls and Indicators (Cont.)
Inlet water
Ball valve
Connects incoming water supply
supply valve
(shown closed)
for the booster.
Inlet water
Ball valve
Connects incoming water supply for
supply valve
(shown open)
the tank fills.
Inlet water
Ball valves
Controls manual fill to wash tank.
supply valves
(shown closed)
Controls manual fill to rinse tank.
Water level
Sight glass
Indicates water level in wash and
gauges
rinse tank.  Water line visible in
center of glass indicates correct
water level in tank.
Tank water
Scaled
Indicates water temperature in
temperature
thermometer
wash and rinse tanks.
gauges
dial
Wash = 150
°
F minimum.
Rinse = 160
°
F minimum.
Final rinse
0-60 PSI
Indicates final rinse water pressure
pressure gauge gauge
during the final rinse.
20-22 PSIG minimum flow pressure.
Final rinse
Scaled
Indicates final rinse temperature
temperature
thermometer
during the final rinse.
gauge
dial
180-195
°
F optimum range.
Drain valves
Ball valves
Controls draining of wash and rinse
(shown closed)
tanks.
Operation
Placard
Complete operation quide to
guide
machine (located on load end
of machine on front panel under
wash gauge next to wash door)