Intel RS2BL080 ユーザーズマニュアル

ページ / 42
Hardware 
Intel® RAID Controller RS2BL080 Technical Product Specification 
 
 
Figure 4 Intel
®
 RAID Smart Battery AXXRSBBU7 
2.3.6 
Diagnostics 
2.3.6.1 
Audible Alarm 
The audible alarm beeps when a drive fails and also during a rebuild. The drive failure alarm 
beeps are: 
ƒ 
Degraded array: Short tone, one second on, one second off. 
ƒ 
Failed array: Long tone, three seconds on, one second off. 
ƒ 
Hot spare commissioned: Short tone, one second on, three seconds off. 
The drive failure tones repeat until the problem is corrected, or until the alarm is silenced or 
disabled. The alarm can be silenced or disabled on the controller’s properties page in the BIOS 
Console or by using the failed drive options pane in the Intel
®
 RAID Web Console 2. 
Silencing the alarm is temporary. If the cause of failure still exists or if an additional failure is 
detected, then the alarm sounds again when the system is rebooted. Disabling the alarm is 
persistent across errors and reboots. When the alarm is disabled, a failure does not cause it to 
sound until it is re-enabled. 
The build alarm tone functions differently. It remains ON during the rebuild. After the rebuild 
completes, an alarm with a different tone sounds to signal that the rebuild is complete. This is a 
one-time, non-repeating tone. 
2.3.6.2 
LED Placement and Function 
The Intel
®
 RAID Controller RS2BL080 contains the following LEDs: 
ƒ 
One surface-mounted heartbeat (“CRT1”) LED (Green Color) to indicate SAS2108 
activity. 
ƒ 
Another surface-mounted system error (“CRT2”) LED (Red Color) to indicate a board 
error. 
ƒ 
Additional LED signaling is available through stake pin connectors on the controller. 
 
 
Revision 1.0
 
 
Intel order number E64388-001 