Roland juno-stage ユーザーガイド

ページ / 256
 
150
Chapter 11. Other Settings
 
[2 (GENERL)]
 
[3 (TX)]
System Menu [4 (MIDI/SYNC)]
 
Parameter
Value
Explanation
Local Switch
 
OFF, ON
Determines whether the internal sound generator is disconnected (OFF) from the controller section 
(keyboard, pitch bend/modulation lever, knobs, buttons, D Beam controller, pedal, and so on); or 
not disconnected (ON).
Normally this is left “ON,” but if you wish to use the JUNO-STAGE’s keyboard and controllers 
to control only external sound modules, set it to “OFF.”
 
Device ID
 
17–32
When you want to transmit or receive System Exclusive messages, set this parameter to match the 
Device ID number of the other MIDI device.
 
Remote Keyboard 
Switch
 
OFF, ON
Set this parameter “ON” when you want to use an external MIDI keyboard instead of the 
JUNO-STAGE’s keyboard.
In this case, the MIDI transmit channel of the external MIDI keyboard can be set to any channel. 
Normally you will leave this parameter “OFF.”
* Turn this “ON” when you want to control the JUNO-STAGE from an external MIDI device when 
performing with the Arpeggio function.
 
Performance Control 
Channel
 
1–16, OFF
Selects the MIDI receive channel used during switching of performances when MIDI messages 
(Program Change/Bank Select) are sent from an external MIDI device.
Set this to “OFF” if performances are not to be switched from an external MIDI device.
* If only a program change is received, and if this parameter setting coincides with the MIDI 
receive channel of a part, priority will be given to switching the performance.
 
Kbd Patch Rx/Tx 
Channel
 
1–16
Channel used to transmit and receive MIDI messages for the Keyboard part in Patch mode
 
USB MIDI
USB-MIDI Thru
 
OFF, ON
If this is “ON,” incoming MIDI messages will be re-transmitted without change from the MIDI OUT 
connector.
 
Parameter
Value
Explanation
Transmit Program Change
 
OFF, ON
Specifies whether Program Change messages will be transmitted (ON) or not (OFF).
 
Transmit Bank Select
 
OFF, ON
Specifies whether Bank Select messages will be transmitted (ON) or not (OFF).
 
Transmit Active Sensing
 
OFF, ON
Specifies whether Active Sensing messages will be transmitted (ON) or not (OFF).
 
Transmit Edit Data
 
OFF, ON
Specify whether changes you make in the settings of a patch, performance will be transmitted as 
system exclusive messages (ON), or will not be transmitted (OFF).
 
Soft Through
 
OFF, ON
Thru function re-transmits all messages received at the MIDI IN connector to the MIDI OUT 
connector without modifying them in any way.
Using the Local Switch
fig.LocalSw.e
When you’re using the JUNO-STAGE with external sequencer software, leave the Local 
Switch turned off. Read the following for details.
Typically, things are hooked up so the data travels as follows: the JUNO-STAGE’s 
keyboard 
→ your external sequencer software → the JUNO-STAGE’s sound generator. 
Normally, the JUNO-STAGE’s keyboard section is internally connected to its sound 
generator section; this internal connection is controlled by the Local Switch. If you turn 
the Local Switch off, the JUNO-STAGE’s keyboard and sound generator sections will be 
independent, allowing you to use the connection described with your external 
sequencer software.
Local Off
(External)
Sequencer
JUNO-STAGE
Keyboard
JUNO-STAGE
Sound Generator
Connecting the JUNO-STAGE to an external sequencer
JUNO-STAGE_e.book 150 ページ 2008年10月17日 金曜日 午後12時27分