Zhone 5100 ユーザーガイド

ページ / 45
Installation and Setup
 2-13
5100-A2-GB21-00
November 1996
Verifying/Changing Switch Settings in Software
Procedure
To verify the switch settings:
1. Select Configuration from the 
HotWire main menu.
2. Select Hardware Setup.
The Hardware Setup window
appears. The setting for the
options shown in this window 
must match the settings on the 
card.
3. If necessary, click on 
 to change 
the settings for these fields:
— Base Address. Areas of memory used by the CPU to distinguish
between the various peripheral devices connected to your system when
transferring or receiving data. The default setting is 380.
— Interrupt No. Signal used by your device to inform the CPU when the
device wants to transfer or receive data. The default setting is 5.
4. Click on one of the following:
— OK to accept the parameters and return to the main menu.
— Cancel to close the window without changes and return the main menu.
— Help to access screen help.
NOTE:
You must select File on the Diagnostics Main menu and then Save to save
the switch settings. Otherwise, the settings will return to the default when you
exit the Diagnostics Utility. If you are installing a board and following all the
Checking Installation procedures, you will be saving the setting in the last
procedure.