Troubleshooting
LED Symptom
Action
All LEDs are on.
If the LEDs remain on for more than ten minutes, the RTU is not 
functional. Unplug the unit and reapply power. If the ALM LED is 
still on, contact the service provider.
ALM LED remains 
on.
The power-on self-test may have failed. Unplug the unit and 
reapply power. If the alarm LED is still on, contact the service 
provider.
ALM and TST LEDs 
are blinking.
Firmware download may be in progress. If firmware download is 
not in progress or the LEDs continue blinking for more than ten 
minutes, contact the service provider. Do not unplug the unit, 
unless instructed to do so by the service provider. 
DSL LED is off.
Verify that the DSL cable is securely installed on both ends. 
Unplug the unit and reapply power. If the problem continues, 
contact the service provider.
DSL LED continues 
to blink after the 
power-on self-test.
The RTU is attempting to establish the DSL link or adjusting the 
rate of the DSL line due to line conditions. If the DSL LED 
continues to blink for more than ten minutes, contact the service 
provider.
DSL LED is on and 
there is no data 
transmission.
The DSL link has been established but there is no data 
transmission. Verify the Ethernet connection. If the problem 
persists, contact the service provider.
DSL and Ethernet 
LEDs are on and 
there is no data 
transmission.
The DSL link and the Ethernet link have been established but 
there is no data transmission. If the problem continues, contact 
the service provider.
Ethernet LED is off.
Verify that the Ethernet cable is securely installed at both ends, 
and at least one PC is connected and powered on.
Verify that the correct straight-through or crossover cable is 
installed. Refer to 
PWR LED is off.
Check that the power cord is securely installed on both ends.
If no LEDs are on, the power supply may be defective. Test the 
outlet to verify power. If the problem persists, contact the 
service provider.
If other LEDs are on, the PWR LED may be burned out. Unplug 
the unit and reapply power; watch all LEDs during the power-on 
self-test to verify that the PWR LED is functioning.
TST LED is on.
A test initiated by the service provider may be active. Wait ten 
minutes. If the TST LED does not go off, contact the service 
provider.