Zhone 7995 ユーザーガイド

ページ / 154
7. Testing
7-12
 
 September 2004
7990-A2-GB20-20
Send Remote Data Channel Loopback
The local termination unit can send an Up or Down sequence to request the start 
or stop of a Data Channel Loopback (DCLB) on a remote unit. 
Procedure
 
To send a Remote DCLB:
1. Position the cursor at the Up or Down selection next to Send Remote DCLB on 
the SYNC Data Port Tests screen.
2. Press the spacebar to select the desired code (Up or Down).
3. Position the cursor at the Start command next to Send Remote DCLB on the 
SYNC Data Port Tests screen.
4. Press Enter.
The Status field is changed to Sending. The Up or Down sequence 
transmission stops automatically after 10 seconds. You cannot stop the 
sequence manually. 
For the loopback to activate, the remote unit must be configured to enable Network 
Initiated Data Channel Loopback.