Amana AEP222VA インストール手順

ページ / 24
5
If connecting to a 4-wire system:
This range is manufactured with the ground connected to the 
neutral by a link. The ground must be revised so the green 
ground wire of the 4-wire power supply cord is connected to the 
cabinet. See “Electrical Connection.”
Grounding through the neutral conductor is prohibited for new 
branch-circuit installations (1996 NEC); mobile homes; and 
recreational vehicles, or an area where local codes prohibit 
grounding through the neutral conductor.
When a 4-wire receptacle of NEMA Type 14-50R is used, a 
matching UL listed, 4-wire, 250-volt, 40-amp, range power 
supply cord (pigtail) must be used. This cord contains 4 copper 
conductors with ring terminals or open-end spade terminals with 
upturned ends, terminating in a NEMA Type 14-50P plug on the 
supply end. 
The fourth (grounding) conductor must be identified by a green or 
green/yellow cover and the neutral conductor by a white cover. 
Cord should be Type SRD or SRDT with a UL listed strain relief 
and be at least 4 ft (1.22 m) long. 
The minimum conductor sized for the copper 4-wire power 
cord are:
40-amp circuit
2 No.-8 conductors
1 No.-10 white neutral
1 No.-8 green grounding
If connecting to a 3-wire system:
Local codes may permit the use of a UL listed, 3-wire, 
250 volt, 40-amp range power supply cord (pigtail). This cord 
contains 3 copper conductors with ring terminals or open-end 
spade terminals with upturned ends, terminating in a NEMA Type 
10-50P plug on the supply end. Connectors on the appliance end 
must be provided at the point the power supply cord enters the 
appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.
INSTALLATION INSTRUCTIONS 
Unpack Range
1.  Do not use oven door handle to lift or move the range. 
2. Remove shipping materials, tape and film from range. Keep 
cardboard bottom under range. Remove oven racks and 
parts package from inside oven. 
3. Take 4 cardboard corners from the carton. Stack one 
cardboard corner on top of another. Repeat with the other 
2 corners. Place them lengthwise on the floor behind the 
range to support the range when it is laid on its back. Using 
2 or more people, firmly grasp the range and gently lay it on 
its back on the cardboard corners. 
4. Pull cardboard bottom firmly to remove. 
5. Use a wrench or pliers to loosen the leveling legs. Adjust the 
leveling legs to the correct height. Leveling legs can be 
loosened to add up to a maximum of 1" (2.5 cm). A maximum 
of 
³⁄₁₆" (5.0 mm) is needed to engage the anti-tip bracket.
 NOTE: If height adjustment is made when range is standing, 
tilt the range back to adjust the front legs, then tilt forward to 
adjust the rear legs. 
6. Place cardboard or hardboard in front of range. Using 2 or 
more people, stand range back up onto cardboard or 
hardboard.  
4-wire receptacle (14-50R)
3-wire receptacle (10-50R)
WARNING
Excessive Weight Hazard
Use two or more people to move and install range.
Failure to do so can result in back or other injury.
A. Cardboard shipping base 
A