Amana AEP222VA インストール手順

ページ / 24
7
Electrical Connection
Power Supply Cord
Direct Wire
1. Disconnect power 
2. Remove the terminal block cover screws located on the back 
of the range. Pull cover down and toward you to remove 
cover.
3. Add strain relief. 
Style 1: Power supply cord strain relief
Assemble a UL listed strain relief in the opening.
Feed the power supply cord through the strain relief on 
the cord/conduit plate on bottom of range. Allow enough 
slack to easily attach the wiring to the terminal block.
Tighten strain relief screw against the power supply cord.
Style 2: Direct wire strain relief
Use Phillips screwdriver to remove screws and rotate/
conduit plate 180º.
Position cord/conduit plate as shown in the following 
illustration.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
A. Hold-down screws 
B. Terminal block cover 
A. UL listed strain relief - large opening
B. Small opening
A
B
A. Large opening
B. Small opening
A. Small opening
B. Large opening
A
B
A
B