Jet 690082 jtm-1 - 9" x 42" 2 hp 3-phase vertical milling machine ユーザーガイド

ページ / 36
 
11
11.  Unwrap and clean elevating (knee) crank and 
install it on its shaft. 
12. Install rubber way covers at front and behind 
table.  
13.  Install belt guards. 
8.6  Lubrication 
  Do not operate this milling 
machine before fully lubricating it. Failure to 
comply may damage machine. 
Familiarize yourself with all lubricating points in 
section 13.0, and fully lubricate this machine before 
operating it. 
9.0  Electrical connections 
 All electrical connections 
must be made by a qualified electrician in 
compliance with all relevant codes. This 
machine must be properly grounded. Failure to 
comply may result in serious injury. 
Confirm that power at the site matches power 
requirements of the mill before connecting to power 
source. 
The JTM-1 turret mill is rated at 2HP, 3PH, 230V 
only.  
The JTM-2 turret mill is rated at 2HP, 1PH, 
115/230V and comes from the factory prewired at 
230V.
 
To convert from 230V to 115V operation (JTM-2 
only): 
1.  Open junction box on motor and change the 
wires according to diagram found on inside of 
cover. 
2. Open Fwd/Rev switch box and change 
connections according to diagram.  
Similar diagrams are found in section 16.0 of this 
manual.  Note: If discrepancies arise, diagrams on 
machine take precedence.
 
It is recommended that the JTM-1 be connected to 
a dedicated 10 amp circuit with a circuit breaker or 
time-delay fuse. Connect the JTM-2, using 230 
volt power
, to a dedicated 40 amp circuit with 
circuit breaker or time-delay fuse, and the JTM-2 
with 115 volt power, to a dedicated 30 amp circuit 
with circuit breaker or time-delay fuse. Local 
codes take precedence over recommendations.
 
9.1  Wire Sizes 
 For circuits which are far away 
from the electrical service box, the wire size must 
be increased in order to deliver ample voltage to 
the motor. To minimize power losses and to 
prevent motor overheating and burnout, the use of 
wire sizes for branch circuits or electrical extension 
cords according to the following table is 
recommended: 
 
Conductor 
Length 
AWG Number 
230/460 Volt Lines 
120 Volt Lines 
0 – 50 Ft. 
No. 14 
No. 14 
50 – 100 Ft. 
No. 14 
No. 12 
Over 100 Ft. 
No. 12 
No. 8 
Table 1 
10.0  Controls 
Refer to Figure 5: 
 
Figure 5: controls 
A.  Motor Lock (Belt Tension) Levers (A, Figure 
5) – Slide levers to loosen motor mounting; 
shift motor to release tension on belts and 
reposition belts for different speed range. 
 
 Disconnect mill from 
power source before changing belt 
position. Reinstall belt guards before 
operating mill.
 
B.  Speed Range Selector (B) – Mill is in high 
speed range when selector is in front position 
(facing operator). Push selector to the side to 
shift into low speed range. Rotate spindle to 
assist engagement, by either turning spindle 
nose by hand or turning drawbar knob with a 
wrench, provided drawbar is pulled up tightly.