2.  Measure the cut piece. 
3.  Adjust pointer accordingly. 
10.3  Feed rate adjustment 
The planer/molder has two speeds that feed the 
work piece, at 10 feet per minute (FPM) for 
improved surface finish when molding and 20 FPM 
for faster planing.   
To change the feed rate gears: 
1. Disconnect machine from power source 
 
(Unplug). 
2.  Remove acorn nut holding the gear cover. 
3.  Remove two hex socket cap screws and two 
washers. 
4.  Remove gears and position according to 
operation. See gear chart (Figure 7). 
5.  Replace screws and washers to hold gears in 
place. 
6.  Replace cover and acorn nut. 
 
Figure 7 
10.4  Adjusting V-Belt Tension 
1. Disconnect machine from power source. 
 
(Unplug) 
2.  Remove stand cover on left of stand. 
3.  Loosen four round cap hex socket slot screws 
holding motor plate to stand. 
4.  Push down on motor to tension belt. Belt is 
tensioned properly when moderate finger 
pressure on belt midway between the two 
pulleys causes approximately 1/4” deflection. 
5.  Tighten four round cap hex socket slot screws. 
6.  Replace stand cover. 
10.5  Knife adjustment 
 
Any adjustment or 
replacement of knives must be done to all three 
knives at the same time. Failure to comply may 
result in an out-of-balance cutterhead which 
will lead to bearing failure.
 
  Use caution when placing 
hands near the cutterhead. Knives are 
extremely sharp. Failure to comply may cause 
serious injury.
 
1. Disconnect machine from power source 
(Unplug). 
2.  Remove screws securing dust hood and dust 
chute. 
3.  Remove dust hood and dust chute. 
4.  With a marking pen, label each knife on the 
cutterhead one, two, and three for easy 
identification. 
5.  Loosen all lock bar screws on blade number 
one. 
6.  With the brass bar and a mallet, carefully tap 
on each end on the outside of the set screws 
for all three lock bars on knife number one.  
This loosens the taper fit of the lock bar. 
7.  Raise or lower knife by turning jack screw.  
Knife is at correct height when knife tip just 
touches center tip of knife gauge (Figure 8). 
 
Figure 8 
8.  Place knife gauge at other end of knife number 
one. 
9.  Raise or lower knife to correct height. 
10.  Tighten knife bar locking screws. Note: Tighten 
each large lock bar independently. Take half 
turns alternating on each end until lock bar is 
tight against the knife. Tighten small lock bar 
after two large lock bars are tight. The small 
lock bar requires two spacers to firmly hold the 
knife. Tighten in the same manner as the large 
lock bars. 
11.  Continue to check knife height with gauge until 
set screws are firmly tightened.