IMPORTANT: If a blade has been cut by using 
snips, the ends of the blade must be ground 
square before welding them together, as shown in 
Figure 12. 
 
Figure 11 
 
Figure 12 
12.2  Removing Teeth 
In fine pitched blades, one or more of the teeth on 
each side of the cut may need to be removed by 
grinding so that the weld area of the blade is 
uniform and the teeth will be uniformly spaced. See 
Figure 11, and refer to section 12.5 Blade grinding
12.3  Welding 
  The welder is designed for 
intermittent use. Repeated welding within a 
short period of time may cause welder to 
overheat.
 
1.  Clean welder jaws and lower jaw inserts. 
2.  Carefully clean ends of blade which will 
contact welder jaws. Remove any dirt, oil, 
scale and oxide. 
  Any rust (oxide) on blade in 
vicinity of weld must be ground off before 
blade can be welded.
 
3.  Turn pressure knob (Figure 13) to “0” position 
(pointed downward). NOTE: There will be 
some resistance when turning knob. 
4.  Insert one end of blade into left clamp. Position 
back edge of blade against back edge of left 
clamp. Then position the end of the blade 
midway between left and right clamps. Tighten 
left clamp. 
5.  Insert opposite end of blade into right clamp. 
Position back edge of blade against back edge 
of right clamp. Then butt the end of blade 
against the other end of blade (the blade ends 
need to be in contact with each other). Tighten 
right clamp. 
6.  Set pressure selector switch (counterclockwise 
rotation) to the approximate setting required 
for the width of the blade being welded. 
  Keep hands clear of weld area 
and clamp jaws during welding. 
7.  Press and hold weld button (Figure 13). When 
weld button is pushed, the left clamp moves to 
the right to apply pressure to the blade ends. 
Simultaneously, sparks will be emitted from the 
blade ends as they are being welded. Do not 
release weld button until blade joint is “red 
hot.” 
 
Figure 13 
8.  Release weld button, and wait 3 or 4 seconds 
until blade returns to original color. Unclamp 
blade. 
9.  Rotate pressure selector switch back to “0”. 
10. Remove blade from clamps, and carefully 
inspect it. The spacing of the teeth should be 
uniform and the weld should be located in 
center of gullet. Misalignment is easily noted at 
this time from the weld appearance. See 
Figure 14 for examples of incorrect welds.  
11.  If the weld is imperfect, refer to section 15.3 for 
possible remedies to any problems. Make 
corrections before annealing.