ISDN TESTER AND ANALYZER D2000
PRO
/D2000Lite/D2000                                                                                USER’S MANUAL
 
 
In Unframed G.703 mode, the line rate is fixed at 2Mbit/s. 
 
The timeslot zero (0) on the E1 frame is used to synchronise the 
frame itself and transport the overhead control bits. In fw version 
previous to 2.56, the Unframed BER test used always the 
timeslot zero (0) of the frame to synchronise and transport the 
overhead control bits. From 2.56 version, with bandwidth set at 
2Mbit, the device sends bits in unframed mode transmitting data  
also on timeslot zero (0) of the E1 frame. The old 2Mbit mode has 
been substituted with “31 channel” mode. 
3.5.4.  Running a BER test over V/X interface 
 
 
VX2000 adapter is fed directly by the D2000
PRO
, this cause a 
decrease of the battery duration. 
The test can be carried out both end-to-end and ‘loop’ mode (single end). In the first 
case it is necessary to put another D2000
PRO
 /VX2000 at the remote end of the line 
(fig. 1-2). In ‘loop’ mode (single end), it is necessary perform a loop over the line. The 
loop can be request to DCE with C141 criterion, through a specific command given to 
the DCE or carrying out a physical loop between TX side and RX side. 