TEI: Use the TEI value assigned to the access. X.25 service uses a fixed value of 
TEI. 
LCI: Logical Channel Identifier, which must be set at one of the values of the LCI 
range used by the access. The instruments uses this value for outgoing calls, while 
accepting any LCI value for incoming calls. 
Window layer 3: Number of level 3 packets which can be transmitted without waiting 
for a reply ("3" by default). 
When you have defined the setup for the X.25 on D Channel test, continue as 
follows: 
3.9.2.  Running an X.25 on D Channel Test 
 
Select ‘Use this setup for testing’. 
 
Connect the instrument as displayed on the screen and 
press the RIGHT CURSOR key.  
 
Start the X.25 test on the D channel. 
The LED RUN goes on and the test results appear on the screen.    
70
 
                           CHAPTER 3 - PERFORMING A MANUAL TEST