Viking Range vgbq0302t インストール手順

ページ / 17
3/8” 
3/8” 
male 
male 
flare 
flare 
dapter
dapter
3/8” 
male 
flare 
adapter
Installer supplied 
flexible gas line
with 3/8” female 
adapter or Viking 
GHS12
Installer supplied 
shut-off valve must 
be easily accessible
3/8” female 
flare adapter
Regulator 
assembly
3/8” male 
flare adapter
24
LP/Propane Fixed Piping Connection
Check with your local gas utility company or
with local codes for instructions on installing
gas supply lines. Be sure to check on type
and size of run and how deep to bury the
lines. If the gas line is too small, the grill will
not function properly.
To connect the supplied regulator assembly
to the incoming flexible gas line, attach with
a 3/8” female flare adapter to the 3/8” male
flare adapter to the regulator assembly.
Ensure that the regulator arrow points in the
direction of the gas flow towards the unit
and away from the supply. Attach the
regulator assembly to the grill unit with the
3/8” female flare adapter on the regulator
assembly to the 3/8” male flare adapter on
the grill. Do not forget to place the
installer supplied gas valve in an
accessible location
.
Connection
Operating Pressure
Supply Pressure 
Standard Residential 1/2” ID
gas service line - 1/2” NPT
male with 3/8” flare adapter.
10.0” W.C.P. LP/Propane.
11” to 14”W.C.P. Nat. If in
excess of 14” W.C.P., a step-
down regulator is required.
Male 
Male 
coupler
coupler
sleeve
sleeve
Male 
coupler
sleeve
Installer supplied 
flexible gas line
with 1/2” female 
adapter or Viking 
GHS12
Installer supplied 
shut-off valve must 
be easily accessible
3/8” female 
flare adapter
7/8” male 
flare adapter
Regulator 
assembly
Natural Fixed Piping Connection
23
Check with your local gas utility company or
with local codes for instructions on installing
gas supply lines. Be sure to check on type
and size of run and how deep to bury the
lines. If the gas line is too small, the grill will
not function properly.
To connect the supplied regulator assembly
to the incoming flexible gas line, attach with
a 1/2” (1.3 cm) female flare adapter to the
7/8” (2.2 cm) male flare adapter on the
regulator assembly. Ensure that the regulator
arrow points in the direction of the gas flow
towards the unit and away from the supply.
Attach the regulator assembly to the grill
unit by pulling back the female coupler
sleeve towards the regulator. Insert the
coupler into the male coupler fitting on the
grill until the sleeve snaps forward securing
the connection. Do not forget to place the
installer supplied gas valve in an
accessible location.
NOTE: If using a Viking GSH12 flexible
hose, remove the 1/2” flare adapter and
attach hose to the 7/8” (2.2 cm) male flare
on the regulator assembly.
Connection
Operating Pressure
Supply Pressure
Standard Residential 1/2” ID
gas service line - 1/2” NPT
male with 7/8” (2.2 cm)
flare adapter.
4.0” W.C.P. Nat.
6” to 10”W.C.P. Nat. If in
excess of 10” W.C.P., a 
step-down regulator is
required.